background image

3.

 Position the handle so the adjustable tongue is in central position vertically position to compensate for movement of  

    guarding in either direction overtime.

Note: 

The distance between the interlock and handle mounting points should within the specified range to allow the tongue to 

fully insert into the interlock mechanism while ensuring the door can be opened and closed without the handle body making 

contact with the unit head.

The unit has been designed to be mounted in 3 different ways; onto extruded aluminium section, flat plate and onto plates or 

guards greater than 25mm thick.

Extruded Aluminium Section

• The handle will be delivered in this configuration.

• Cut a Ø50mm hole for the handle boss of the red escape release handle to go through the guard in the appropriate  

  location.

• Fix the handle to the Aluminium section using 2 x M6 T-Nuts and 2 x M6 Bolts.

• Use a third M6 bolt to attach the rear mounting to the guard.

• A spacer may be required for the rear fixing.

Figure 7 & 8: 

Plates and Guards up to 25mm thick

• The handle will be delivered in this configuration.

• Cut a Ø50mm hole for the handle boss of the red escape release handle to go through the plate / guard in the appropriate  

  location.

• Cut 3 x M6 threads into plate / guard using the panel cutout dimensions given below in Figure 9.

• Insert red escape release handle through Ø50mm hole and secure handle to plate / guard using 3 x M6 Bolts.

Figure 9:

Plates or Guards between 25mm and 40mm thick

To mount to guards greater than 25mm thick but less than 40mm thick, the red escape release handle assembly may need to 

be removed and refitted through the guard. If this is required, care must be taken to ensure the correct cam orientation and 

operation during reassembly – Contact your Fortress Representative for more details. Once re-assembled, secure the handle 

to the guard using the instructions detailed above for plates and guards up to 25mm thick.

www.fortressinterlocks.com

Fortress

Interlocks

ALUMINIUM SECTION

M6 T-NUT

M6 T-NUT

3 X M6 MOUNTING

BOLTS

RED EMERGENCY HANDLE

SILVER ACCESS HANDLE

Operating Instructions: Single Action Escape Release Head & Handle 

7

RED ESCAPE RELEASE  

HANDLE

ALUMINIUM 

SECTION

3 X M6 MOUNTING 

BOLTS

SILVER ACCESS HANDLE

M6 T-NUT

www.fortressinterlocks.com

Fortress

Interlocks

ALUMINIUM SECTION

M6 T-NUT

M6 T-NUT

3 X M6 MOUNTING

BOLTS

RED EMERGENCY HANDLE

SILVER ACCESS HANDLE

M6 T-NUT

RED ESCAPE 

RELEASE HANDLE

FLAT PLATE UP 

TO 25MM THICK

3 X M6 MOUNTING 

BOLTS

EXTERNAL PANEL CUTOUT DIMENSIONS

M6 THD

(3 PLACES)

Ø50 THRU ALL

MINIMUM

Summary of Contents for Fortress amGardpro

Page 1: ...dle Escape Release Handle EI2 Left Escape Release Handle EI4 Right Escape Release Handle Allowing Closing of Door From Inside EJ2 Left Escape Release Handle Allowing Closing of Door From Inside EJ4 Ri...

Page 2: ...4 Prevents insertion of actuator when locked out amGardpro Escape Release Handle Safety Functions Part No Safety Function 1 Provides link from interlock to door EI EJ Safety Function 2 Internal handle...

Page 3: ...E DATE 25 02 2020 ISSUE 0 AMGARD PRO I7 A7 ESCAPE RELEASE HEAD DIMENSIONS DWG NO SD 00018 DROPDOWN LOCKOUT OPEN DROPDOWN LOCKOUT CLOSED I7 ALL IN ONE ESCAPE RELEASE HEAD WITH PADLOCKABLE DROPDOWN LOCK...

Page 4: ...GARD PRO ESCAPE RELEASE HEAD AND HANDLE DWG NO SD 00018 RELATIVE MOUNTING DIMENSIONS BETWEEN I6 I7 A6 A7 ESCAPE RELEASE HEAD AND EI EJ ESCAPE RELEASE HANDLE Operating Instructions Single Action Escape...

Page 5: ...5 1 1 Scale of Mounting Hole Positions...

Page 6: ...either by vibration or by personnel using standard tools 7 Ensure each of the three M8 head fixings are used to guarantee correct operation and maximum head retention force 8 The installation and ope...

Page 7: ...plate guard in the appropriate location Cut 3 x M6 threads into plate guard using the panel cutout dimensions given below in Figure 9 Insert red escape release handle through 50mm hole and secure hand...

Page 8: ...A7 type Head The A6 and A7 type heads require no additional resetting procedure after an escape release operation Closing the guarding door and re inserting the tongue into the head using the exterior...

Page 9: ...ns Installation and electrical connection not performed by authorised personnel Non implementation of functional checks Protection Against Environmental Influences A lasting and correct safety functio...