Halma BEA DK-12 User Manual Download Page 9

TROUBLE-
SHOOTING –  

 

 

 

initial powering 

 

    

DK-1 will not set-up upon 

Page 9 of 10 

75.0082.05   20080125 

 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

PROBLEM                               

O

                    

    PR BABLE CAUSE             

    CORRECTIVE ACTION 

1.  Check terminals 1 & 2 for proper voltage  
     24 V AC/DC + 10%. 

Make certain that the field of detection is all

clear during the set-up and that all lenses 
are installed on the DK-12.  If detection of 
movement is encountered upon initial set-
up, the DK-12 will continuously flash red at 

2. 

 

+ 2 Hz. The DK-12 will also not set-up if 
permanent stationary objects are extremel
close to the sensor.  Ensure that, not only 
is the detection field all clear, but that the 
sensor is mounted properly (using the D
12 mounting block if necessary).  If the 
mounting block is not used, and the 
backside of the sensor is less than 3” to the 
face of the door, it may be in saturation due 

K-

 

3. 

 

4. 

lockout device or the lockout safety beams. 

 

4. 

y   

 

beams or lockout relay. 

to the door. Install the optional mounting
block if necessary. 

Ensure that all wiring connections have 

1. 

Improper input voltage

2. 

DK-12 is in detection 

3. Improper 

wiring 

Problem may exist with safet

been properly made.  Refer to wiring on
Page 3. 

Ensure that no problems exist with the 

DK-12 will not set-up after 
program changes have been 
made

1. 

K-12 to learn both 

door positions. 

1. 

2. 

up has been completed. 

4. Improper relay output configuration 

1. 

 

 set-

2. 

 

 

3. 

he 

 

4. 

relay would close upon detection. 

Door needs to complete one open – 

close cycle for D

Activate the door to allow a full open and 
close cycle.  Allow the door to remain in the 
closed position to allow set-up.  Activate the 
door open and allow the DK-12 to learn 

door open set-up.  Normal operation should 
resume once both set-ups are complete. 
Remove and re-apply power to the DK-12.  
Allow set-ups to complete for door open and 
door closed positions. 

Check to ensure that there is no detection

occurring at the DK-12.  If the Red LED is 
on steady, there is detection. Make sure 
there have been no changes in the field of 
detection since set-up.  If permanent 

Door

ill not open once set-

 w

1. DK-12 is in detection. 
2. Improper wiring 
3. Lockout safety beams are in 

detection 

changes have occurred, launch a new
up and re-test door. 

Remove the output wires (common, 

normally open, normally closed) from the 
DK-12. 

CAUTION – there may possibly be

no safety on the door when this test is 
performed.

 Activate the door control, if the

door opens, the fault exists with DK-12 or 
related wiring. If door does not open, the 
faults may exist with the door control or it’s 
related wiring. 

Disconnect the green & blue wires from t

LO-21 to the door control safety and 
common terminals.  If door opens when 
triggered, fault lies within the lockout safety 
beam set, or possibly with the LO-21.  Refer
to the LO-21 troubleshooting procedures in 
the respective manual. 

Check to insure proper relay output setting. 

Refer to page 6.  Typically, relay setting 
should be ‘Normally Open’.  This means the 

Summary of Contents for BEA DK-12

Page 1: ...attern left right 4 W x 4 D see pattern chart Mounting angle 20 26 32 Power supply 12 24 V AC or DC 10 Frequency 50 or 60 Hz Consumption 2 W Output SPDT relay Max voltage relay contacts 60 V DC 125 V...

Page 2: ...ered with relation to the door opening If the DK 12 is used on any door with an opening greater than 6 it is highly recommended to use more than one DK 12 Pattern selections will depend on the door an...

Page 3: ...nsor and leave a few inches hanging out Do not drill holes in the aluminum mounting bracket This voids warranty 4 Slide the sensor into the mounting bracket at the desired angle The greater the mounti...

Page 4: ...r installation no access code is required REMOTE CONTROL To adjust the DK 12 stand to the left of the detector aim the remote towards the left side of the detector with the end cap removed at a distan...

Page 5: ...grammed separately for door open and door closed position After pressing the SENSITIVITY key the red LED flashes quickly After pressing a number button the red LED flashes slowly Door closed 8 Door Op...

Page 6: ...p for the respective door position using Magic Wand 1 door open or 2 door closed After pressing the DEFAULT VALUES key the red LED flashes quickly After pressing a number button the sensor launches an...

Page 7: ...ver is located inside of DK 12 near terminal Press the function button followed by the number that corresponds to the desired setting 4 With the door in the CLOSED position select the pattern size and...

Page 8: ...e shape of the pattern it is necessary to re launch a new set up for both the open and closed positions of the door PATTERN CHART MOUNTING HEIGHT 7 3 Wide Pattern ABCD Narrow Pattern BC Narrow Pattern...

Page 9: ...would close upon detection Door needs to complete one open close cycle for D Activate the door to allow a full open and close cycle Allow the door to remain in the closed position to allow set up Act...

Page 10: ...e replace faulty DK 12 HELPFUL HINT If the DK 12 will not enter into a door open set up simply unlock the sensor with BEA s remote control and force a door open set up see bottom page7 If incorrect If...

Reviews: