Halma BEA DK-12 User Manual Download Page 7

 

 
 

PROGRAMMING/ 
SETUP

 

The DK-12 has been programmed with factory-default settings.  They are defined on the chart on page 5 and 6.  
Please review the factory default settings before making any changes to the DK-12.  If at any time the factory default 
settings are appropriate for your application, you 

DO NOT

 have to change them. Only change the parameters that are 

needed to customize your application.  
 
With the help of data wires from LO-21/SS-21, the DK-12 has the capability of having two different memory locations: 
DOOR OPEN and DOOR CLOSED.  This feature enables the DK-12 to have different settings for the 

pattern 

selection

 and the 

sensitivity

 in both the DOOR OPEN and DOOR CLOSED positions.  All the other settings of the 

DK-12 remain the same, independent of the position of the door.   

 
DOOR OPEN & DOOR CLOSED memory location capabilities: 
 

Dependent on door position 

Independent of door position  

Pattern selection 

Relay hold time 

Sensitivity Relay 

mode 

 

Auto learn time 

 Frequency 

 
To program the DK-12, complete the following steps: 
 

1. 

Review the default settings. 

 
2. 

Determine which settings need to be changed. 

 
3. 

Change any setting that is independent of the door position (relay hold time, relay mode, auto learn, 
frequency): 

 

 

Remove left end cap. 

 

Stand within 6’ of the left side of the sensor (do not be afraid to stand in the pattern area, but move 

out of the pattern after making a change). 

 

Point the remote control toward the opening (the receiver is located inside of DK-12 near terminal)  

 

Press the function button followed by the number that corresponds to the desired setting. 

 
4. 

With the door in the CLOSED position, select the pattern size and the sensitivity 
setting desired. 

+ 1 

 
5.  Launch a DOOR CLOSED set-up with the remote: The LED will flash for 

approximately 10 sec. and stop once the set-up is complete (see set-up for more 
details). 

 

6. 

Place the door into hold open. 

 

7. 

With the door in the OPEN position, select the pattern size and the sensitivity 
setting desired. 

+ 2 

 

8.  Launch a DOOR OPEN set-up with the remote: The LED will flash for 

approximately 10 sec. and stop once the set-up is complete (see set-up for more 
details). 

 

HELPFUL NOTES: 

 
Once a set-up is launched the LED will flash at 5 Hz for approximately 10 seconds. 
 

 

If the set-up is successful, the LED will go off and the detector will function normally. 

 

 

If the set-up is not successful, the LED will continue to flash, but at a lower frequency of 2.5 Hz. 

 

 

Possible problems during setup: 

 

a. 

If a person walks through the detection zone during the set-up, the set-up can be disturbed. 

 
b. 

If a very reflective object is placed within 32 inches from the DK-12, it can blind the detector and make 
the set-up impossible. 

 

c. 

If the set-up that corresponds to the DOOR OPEN state is launched when the door is closed, the set-up 
will be ignored and vice versa. 

 
NOTE: 

When two DK-12’s are installed on the same door, place the end cap on one DK-12 and program the 
open DK-12.  Once the first DK-12 is programmed, install its end cap and remove the second DK-12’s 
end cap and repeat the programming procedure. 

75.0082.05   20080125 

Page 7 of 10 

Summary of Contents for BEA DK-12

Page 1: ...attern left right 4 W x 4 D see pattern chart Mounting angle 20 26 32 Power supply 12 24 V AC or DC 10 Frequency 50 or 60 Hz Consumption 2 W Output SPDT relay Max voltage relay contacts 60 V DC 125 V...

Page 2: ...ered with relation to the door opening If the DK 12 is used on any door with an opening greater than 6 it is highly recommended to use more than one DK 12 Pattern selections will depend on the door an...

Page 3: ...nsor and leave a few inches hanging out Do not drill holes in the aluminum mounting bracket This voids warranty 4 Slide the sensor into the mounting bracket at the desired angle The greater the mounti...

Page 4: ...r installation no access code is required REMOTE CONTROL To adjust the DK 12 stand to the left of the detector aim the remote towards the left side of the detector with the end cap removed at a distan...

Page 5: ...grammed separately for door open and door closed position After pressing the SENSITIVITY key the red LED flashes quickly After pressing a number button the red LED flashes slowly Door closed 8 Door Op...

Page 6: ...p for the respective door position using Magic Wand 1 door open or 2 door closed After pressing the DEFAULT VALUES key the red LED flashes quickly After pressing a number button the sensor launches an...

Page 7: ...ver is located inside of DK 12 near terminal Press the function button followed by the number that corresponds to the desired setting 4 With the door in the CLOSED position select the pattern size and...

Page 8: ...e shape of the pattern it is necessary to re launch a new set up for both the open and closed positions of the door PATTERN CHART MOUNTING HEIGHT 7 3 Wide Pattern ABCD Narrow Pattern BC Narrow Pattern...

Page 9: ...would close upon detection Door needs to complete one open close cycle for D Activate the door to allow a full open and close cycle Allow the door to remain in the closed position to allow set up Act...

Page 10: ...e replace faulty DK 12 HELPFUL HINT If the DK 12 will not enter into a door open set up simply unlock the sensor with BEA s remote control and force a door open set up see bottom page7 If incorrect If...

Reviews: