MECHANICAL 
INSTALLATION

 

1. 

Remove the left endcap by removing the two Phillips head screws.  Use the Allen key provided in the 
screw kit to loosen the setscrew.  Finally, slide the sensor from the mounting bracket. 

 

 

 

 

 

REMOVE ENDCAP 

LOOSEN SETSCREW 

REMOVE SENSOR FROM BRACKET 

Page 2 of 10 

75.0082.05   20080125 

 
 

2. 

Select a mounting position for the sensor.  For single door or a pair of doors, the sensor should be 
centered with relation to the door opening.  If the DK-12 is used on any door with an opening greater than 
6’, it is highly recommended to use more than one DK-12.  Pattern selections will depend on the door and 
the mounting position.   See the chart and diagram on the following pages for pattern selection. 

 

             

 

 

 

 
 
 
 
 

 

 

Left Hand Swing Door

Double Swing Door (opening less than 6’) 

Right Hand Swing Door

Double Swing Door (opening over 6’) 
See page 7 for selecting the pulsing frequency of two  
DK-12’s located next to each other

 

 
 
 
NOTE:  Be sure that there are no objects within the view of the sensor lenses, such as a door-operating arm. 
 
 
 
 
 
 
 

Summary of Contents for BEA DK-12

Page 1: ...attern left right 4 W x 4 D see pattern chart Mounting angle 20 26 32 Power supply 12 24 V AC or DC 10 Frequency 50 or 60 Hz Consumption 2 W Output SPDT relay Max voltage relay contacts 60 V DC 125 V...

Page 2: ...ered with relation to the door opening If the DK 12 is used on any door with an opening greater than 6 it is highly recommended to use more than one DK 12 Pattern selections will depend on the door an...

Page 3: ...nsor and leave a few inches hanging out Do not drill holes in the aluminum mounting bracket This voids warranty 4 Slide the sensor into the mounting bracket at the desired angle The greater the mounti...

Page 4: ...r installation no access code is required REMOTE CONTROL To adjust the DK 12 stand to the left of the detector aim the remote towards the left side of the detector with the end cap removed at a distan...

Page 5: ...grammed separately for door open and door closed position After pressing the SENSITIVITY key the red LED flashes quickly After pressing a number button the red LED flashes slowly Door closed 8 Door Op...

Page 6: ...p for the respective door position using Magic Wand 1 door open or 2 door closed After pressing the DEFAULT VALUES key the red LED flashes quickly After pressing a number button the sensor launches an...

Page 7: ...ver is located inside of DK 12 near terminal Press the function button followed by the number that corresponds to the desired setting 4 With the door in the CLOSED position select the pattern size and...

Page 8: ...e shape of the pattern it is necessary to re launch a new set up for both the open and closed positions of the door PATTERN CHART MOUNTING HEIGHT 7 3 Wide Pattern ABCD Narrow Pattern BC Narrow Pattern...

Page 9: ...would close upon detection Door needs to complete one open close cycle for D Activate the door to allow a full open and close cycle Allow the door to remain in the closed position to allow set up Act...

Page 10: ...e replace faulty DK 12 HELPFUL HINT If the DK 12 will not enter into a door open set up simply unlock the sensor with BEA s remote control and force a door open set up see bottom page7 If incorrect If...