Halma BEA DK-12 User Manual Download Page 8

 

 

 

SETUP  
INFORMATION 

 

PATTERN SELECTION   

The DK-12 detection zone is made up of 4 small zones placed next to each other, perpendicular to the door.  The 
4 zones are shown in the diagram below.   There are 6 different patterns that are possible with combinations of the 
4 detection zones.  Please refer to the chart on the following page for the dimensions of the DK-12 detection zones 
at different mounting heights and mounting angles.  
 
The shape of the pattern can be different when the door is open and when it is closed.  In the detector, there is no 
link between the pattern for the open door and the pattern for the closed door.  The shape of the pattern is 
accessible as a function of door state and only the corresponding shape can be adjusted.  The DK-12 receives 
input from the LO-21 or SS-21 as to the state of the door via the data lines. 

 

Header 

DK-12 

Width

A

B

C

D

Depth

 

 

 

After any change in the shape of the pattern, it is necessary to re-launch a new set-up for both the open and 
closed positions of the door. 

 

PATTERN 
CHART 

 

 

MOUNTING HEIGHT 
7’3”

 

Wide Pattern  
ABCD 

Narrow Pattern 
 BC 

Narrow Pattern  
AB or CD 

Asymmetrical Pattern  
ABC or BCD 

ANGLE:  20

°

 

width x depth 

width x depth 

width x depth 

width x depth 

, #9 

5’ x 3’3” 

2’3” x 2’3” 

2’6” x 3’ 

3’6” x 3’3” 

, #0 

4’ x 2’6” 

2’ x 2’ 

2’ x 2’3” 

2’3” x 2’ 

ANGLE:  26

°

 

 

 

 

 

, #9 

5’ x 4’3” 

2.3’ x 4’ 

2’6” x 3’6” 

4’ x 4’ 

, #0 

4’ x 3’3” 

1’6” x 2’6” 

2’ x 2’6” 

3’ x 3’3” 

ANGLE:  32

°

 

 

 

 

 

, #9 

6’ x 6’ 

2’3” x 5’ 

2’6” x 4’ 

3’6” x 5’6” 

, #0 

3’6” x 4’3” 

2’ x 4’ 

2’ x 3’6” 

2’3” x 4’ 

MOUNTING HEIGHT 

8’3”

 

 

 

 

ANGLE:  20

°

 

 

 

 

 

, #9 

5’3” x 3’6” 

2’6” x 3’3” 

2’6” x 3’ 

3’6” x 3’6” 

, #0 

3’3” x 2’6” 

2’ x 2’3” 

2’ x 2’3” 

2’3” x 2’6” 

ANGLE:  26

°

 

 

 

 

 

, #9 

5’3” x 5’6” 

2.3’ x 3’6” 

2’3” x 3’3” 

4’ x 3’6” 

, #0 

3’3” x 2’6” 

1’3” x 2’3” 

2’ x 2’3” 

2’3” x 2’6” 

ANGLE:  32

°

 

 

 

 

 

, #9 

5’6” x 6’9” 

3’ x 6’ 

3’3” x 5’6” 

4’ x 6’9” 

, #0 

3’3” x 4’6” 

1’6” x 4’ 

1’6” x 4’ 

3’ x 4’ 

MOUNTING HEIGHT 9’6” 

 

 

 

 

ANGLE:  20

°

 

 

 

 

 

, #9 

6’6” x 4’6” 

2.3’ x 4’6” 

2’3” x 4’3” 

4’3” x 4’6” 

, #0 

4’ x 3’3” 

1’6” x 3’3” 

1’6” x 2’6” 

2’3” x 3’ 

ANGLE:  26

°

 

do not use 

 

 

 

ANGLE:  32

°

 

do not use 

 

 

 

NOTE:  The above dimensions are given as references only! They are to aid in pattern selection. 

 

 
 

 

75.0082.05   20080125 

Page 8 of 10 

Summary of Contents for BEA DK-12

Page 1: ...attern left right 4 W x 4 D see pattern chart Mounting angle 20 26 32 Power supply 12 24 V AC or DC 10 Frequency 50 or 60 Hz Consumption 2 W Output SPDT relay Max voltage relay contacts 60 V DC 125 V...

Page 2: ...ered with relation to the door opening If the DK 12 is used on any door with an opening greater than 6 it is highly recommended to use more than one DK 12 Pattern selections will depend on the door an...

Page 3: ...nsor and leave a few inches hanging out Do not drill holes in the aluminum mounting bracket This voids warranty 4 Slide the sensor into the mounting bracket at the desired angle The greater the mounti...

Page 4: ...r installation no access code is required REMOTE CONTROL To adjust the DK 12 stand to the left of the detector aim the remote towards the left side of the detector with the end cap removed at a distan...

Page 5: ...grammed separately for door open and door closed position After pressing the SENSITIVITY key the red LED flashes quickly After pressing a number button the red LED flashes slowly Door closed 8 Door Op...

Page 6: ...p for the respective door position using Magic Wand 1 door open or 2 door closed After pressing the DEFAULT VALUES key the red LED flashes quickly After pressing a number button the sensor launches an...

Page 7: ...ver is located inside of DK 12 near terminal Press the function button followed by the number that corresponds to the desired setting 4 With the door in the CLOSED position select the pattern size and...

Page 8: ...e shape of the pattern it is necessary to re launch a new set up for both the open and closed positions of the door PATTERN CHART MOUNTING HEIGHT 7 3 Wide Pattern ABCD Narrow Pattern BC Narrow Pattern...

Page 9: ...would close upon detection Door needs to complete one open close cycle for D Activate the door to allow a full open and close cycle Allow the door to remain in the closed position to allow set up Act...

Page 10: ...e replace faulty DK 12 HELPFUL HINT If the DK 12 will not enter into a door open set up simply unlock the sensor with BEA s remote control and force a door open set up see bottom page7 If incorrect If...