The mounting bracket may be to a header or to the ceiling.  Select the location for mounting, and secure solidly with 
screws provided.  To mount the unit to the ceiling, the two plastic plugs will need to be removed. 

MECHANICAL 
INSTALLATION 
(CON’T)

 

 

WALL MOUNT 

CEILING MOUNT 

 

 

 

3. 

The installer must provide means for routing wires from the sensor to the inside of the header.  The 
terminal block is located at the left end of the sensor.  At the back edge of the left and right end covers, 
there is a small punch out slot to allow the concealed passage of wire into the sensor.  A slot is also 
provided at the top of the sensor, should wires need to be routed from the opposite end of the sensor.  
Locate the wire passage hole on the header to keep it concealed.  Once the hole is located and drilled, 
pull the 6-conductor wire from the header to the sensor, and leave a few inches hanging out.    
Do not drill holes in the aluminum-mounting bracket. (This voids warranty) 

 

4. 

Slide the sensor into the mounting bracket at the desired angle.  The greater the mounting angle, the 
further the pattern will be from the threshold. 

 

 

 

 

20° (standard position) 

26° 

32° 

 

5. 

Tighten the setscrew and replace the endcap. 

 

 

 

 
NOTE:  BEA recommends the use of the WHU (weather protection hood) for any DK-12 that is installed outside and 

is exposed to direct weather.  The circuit board of the DK-12 is not waterproof; therefore, it is susceptible to 
water damage.  Any DK-12 that is returned due to water damage will be considered out of warranty. 

 
 

ELECTRICAL 
INSTALLATION

 

At the left side of the sensor, remove the 7 pin terminal connector by pulling it straight out.  Connect as shown:  

 

 

 

 

 

 

PIN WIRE 

COLOR 

  

RED 

  

BLACK 

  

WHITE 

  

GREEN 

  

 

  

BROWN 

  

BLUE 

 

Refer to the wiring diagram in the respective User’s Guide 
for the type of Lockout Module being used (i.e. LO-21, 
LO-21U, MC-15, etc.) for all necessary wiring.  
 

 

75.0082.05   20080125 

Page 3 of 10 

Summary of Contents for BEA DK-12

Page 1: ...attern left right 4 W x 4 D see pattern chart Mounting angle 20 26 32 Power supply 12 24 V AC or DC 10 Frequency 50 or 60 Hz Consumption 2 W Output SPDT relay Max voltage relay contacts 60 V DC 125 V...

Page 2: ...ered with relation to the door opening If the DK 12 is used on any door with an opening greater than 6 it is highly recommended to use more than one DK 12 Pattern selections will depend on the door an...

Page 3: ...nsor and leave a few inches hanging out Do not drill holes in the aluminum mounting bracket This voids warranty 4 Slide the sensor into the mounting bracket at the desired angle The greater the mounti...

Page 4: ...r installation no access code is required REMOTE CONTROL To adjust the DK 12 stand to the left of the detector aim the remote towards the left side of the detector with the end cap removed at a distan...

Page 5: ...grammed separately for door open and door closed position After pressing the SENSITIVITY key the red LED flashes quickly After pressing a number button the red LED flashes slowly Door closed 8 Door Op...

Page 6: ...p for the respective door position using Magic Wand 1 door open or 2 door closed After pressing the DEFAULT VALUES key the red LED flashes quickly After pressing a number button the sensor launches an...

Page 7: ...ver is located inside of DK 12 near terminal Press the function button followed by the number that corresponds to the desired setting 4 With the door in the CLOSED position select the pattern size and...

Page 8: ...e shape of the pattern it is necessary to re launch a new set up for both the open and closed positions of the door PATTERN CHART MOUNTING HEIGHT 7 3 Wide Pattern ABCD Narrow Pattern BC Narrow Pattern...

Page 9: ...would close upon detection Door needs to complete one open close cycle for D Activate the door to allow a full open and close cycle Allow the door to remain in the closed position to allow set up Act...

Page 10: ...e replace faulty DK 12 HELPFUL HINT If the DK 12 will not enter into a door open set up simply unlock the sensor with BEA s remote control and force a door open set up see bottom page7 If incorrect If...