29
Genesis™ Matrix Switches
3.2.8 To Read Volume Units (VU sound level) of output #1
This command returns the height of hypothetical bar LED indicator having a
height of 16 segments. It will return a number from 0 to 16 with 10 being 0 db
levels. So if the output #1 is at 0 dB (900 mV p-p Sine wave) it returns 10. This
value is 0-16 regardless of the type of matrix.
Command:
RB<cr>
stands for Read Bar
Response:
0 ~ 16<cr>
10 would be 0 dB on a VU meter
3.2.9 To Read Temperature inside the Matrix
Command:
RT<cr>
stands for Read Temperature
Response:
Temperature in degrees C = 32.500000<cr>
Temperature in degrees F = 90.500000<cr>
3.2.10 To Read the Firmware Version
Command:
RI<cr>
stands for Read Identity
Response:
Unit's name:
←
User defined name of the unit
Version 2.4
←
Firmware Version
Build # 7
←
Build number (for mfg purposes only)
VSM-I-A-8-8
←
Model #/Characteristics of the unit
3.2.11 To Read Supply Voltages
The supply voltages consist of clock battery voltage, 5V supply, and 12V supply.
Command:
RV<cr>
stands for Read Voltages
Response:
RTC Battery Voltage = 2.9876704
+5V Supply = 4.9473252
+12V Supply = 12.4646893