25
Genesis™ Matrix Switches
3.2 Control Commands (RS-232 and IP)
The Genesis™ Matrices can be controlled via an external control system by using
either the standard RS-232 or the optional IP port. Any program capable of
standard serial communication in ASCII format is capable of working with the
matrix. Most PCs with Windows™ OS have HyperTerminal™ or equivalent.
There are also many free Terminal Emulator and Telnet software available for
download on the internet.
Note on RS-232 port availability on your PC
Most PCs and notebooks do not have a serial port. So to program the
Matrix Switch you may need a USB to RS-232 Serial converter. These
are available from Hall Research (Model USB-RS232-1).
Figure 15 – USB to RS-232 Adapter
Use Figure 8 to connect the unit to the PC’s serial port. Use 9600 Baud, 8 bits, No
Parity, 1 Stop bit, No flow control.
Upon power up, the Matrix will output a screen similar to the figure below
through its serial port(s).
Figure 16 – Power on screen
Note on RS-232 commands
When the front panel is in use (for example to make new ties or recall
presets, etc), only status request commands are accepted. Any other
command will be prompted with the following response:
Front panel is in use<cr>
All front panel operations have a timeout function so even if a user
started to use the panel but forgot to finish the process, it will time out
in a few seconds and full serial port functionality will be restored.
© Hall Research
Version 2.4
Build # 17
VSM-16-16