Page
73
SmartFOAM
Upon initial power-up with the foam tanks empty, the dis-
play on the controller unit will display a warning bar indi-
cating that the foam tank is low.
Figure 58: Low Foam Tank Warning
1. Fill the foam concentrate tank with WATER. The
“
low foam tank” warning
indication clears from
the display indicating the low tank level sensor is
operating properly.
2. Place the bypass valves handle to the
BYPASS
position to check the foam pump operation.
Place a calibrated five gallon container at the
discharge end of the bypass hose.
3. Place the system in simulated flow mode:
a. Press the MENU button.
b. In the menu select the “simulated water
flow” button.
c. In the simulated water flow screen press
the ON/OFF button to toggle simulated
water flow. The icon indicates the cur-
rent state.
d. Set the simulated flow to 100 GPM by
using the INCR/DECR buttons.
e. Press the MENU button to return to the
menu.
f.
Press the RETURN button to return to
the operation screen.
Figure 59: Setting Simulated Water Flow
Summary of Contents for SmartFOAM
Page 3: ...Page 2 SmartFOAM NOTES...
Page 16: ...Page 15 SmartFOAM SYSTEM DIAGRAM Figure 6 Typical Hale SmartFOAM 2 1A and 1 7AHP System...
Page 17: ...Page 16 SmartFOAM Figure 7 SmartFOAM 3 3 5 0 6 5 Single Tank System with In line Strainer...
Page 18: ...Page 17 SmartFOAM Figure 8 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandIn lineStrainer...
Page 19: ...Page 18 SmartFOAM Figure 9 SmartFOAM 3 3 5 0 6 5 Single Tank withMSTandFSSeriesStrainer...
Page 20: ...Page 19 SmartFOAM Figure 10 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandIn lineStrainers...
Page 21: ...Page 20 SmartFOAM Figure 11 SmartFOAM 3 3 5 0 6 5 Dual Tank withMDTIIandFSSeriesStrainer...
Page 22: ...Page 21 SmartFOAM Figure 12 SmartFOAM 3 3 5 0 6 5 Dual Tank withADTandIn lineStrainers...
Page 23: ...Page 22 SmartFOAM Figure 13 SmartFOAM 3 3 5 0 6 5 Dual Tank withADTandFSSeries Strainers...
Page 48: ...Page 47 SmartFOAM Figure 28 Typical 4 Inch Check Valve Installation Midship Pump...
Page 59: ...Page 58 SmartFOAM Figure 43 ADT Option Air Hose Connections Part 2...
Page 68: ...Page 67 SmartFOAM Figure 55 Top Mount Low Level Sensor Assembly...
Page 77: ...Page 76 SmartFOAM NOTES...
Page 90: ...89 Page 89 SmartFOAM NOTES...