FoamLogix, Model 2.1A and 1.7AHP Class
“A”
Electronic Foam Proportioning Systems
54
27: Display - Flow Sensor Calibration
FLOW SENSOR CALIBRATION
Verify flow sensor calibration during NFPA/UL testing
of the apparatus and delivery to end user.
IMPORTANT!
AN ACCURATE FLOW MEASURING DEVICE MUST
BE USED TO MEASURE THE WATER FLOW WHEN
CALIBRATING THE FLOW SENSOR. USE A SUITABLE
SIZE, SMOOTH BORE, NOZZLE AND AN ACCURATE
AND CALIBRATED PITOT GAUGE INSTRUMENT.
HAND HELD PITOT GAUGES ARE USUALLY NOT
VERY ACCURATE.
MAKE SURE THE SYSTEM IS CALIBRATED WITH AN
ACCURATE FLOW MEASURING DEVICE.
Figure 26: Display - Password and Calibration Modes
1. Determine the water flow normally expected
from the discharge outlet and establish flow.
2. Make sure the water flow established is within
the range of the flow sensor monitoring the
discharge.
For example, establish a flow rate of 150 GPM
(568 LPM) of water through a nozzle and Pitot
system. Compare the calculated flow value to
the value shown on the control unit display.
SELECT DISPLAY
Press and
HOLD
Continued to
HOLD
Displayed when
is pressed
Displayed when
is pressed
Pressed in
sequence to
enter passwords
Release when
CAL is shown
Summary of Contents for FoamLogix 1.7AHP
Page 4: ...FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 4 NOTES...
Page 10: ...FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 10...
Page 14: ...FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 14 NOTES...
Page 28: ...FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 28 NOTES...
Page 52: ...FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 52 NOTES...
Page 68: ...FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 68 NOTES...
Page 79: ...NOTES FoamLogix Model 2 1A and 1 7AHP Class A Electronic Foam Proportioning Systems 77...