Halcyon Streamline P-Valve Installation Manual Download Page 8

8

use the optional set screw to make sure that the external cap cannot be removed 
from the valve, gently tighten the set screw with an Allen wrench until the head 
almost touches the cap body. Test to ensure that the external cap is able to be 
loosened approximately two full turns and then stops. If the cap seems to bind, 
back the set screw out slightly until the movement is unimpeded. Use of the set 
screw is optional– however it can prevent accidental loss of the cap. 

Valve Operation

When the cap is turned clockwise and snug against the suit shoulder, the valve is 
completely closed and inoperable. No fl uids can be discharged or enter the suit. 
When the cap is turned counterclockwise approximately two turns, the valve is 
operational and fully automatic. Fluids can be discharged at will, but water can-
not re-enter the valve due to the one-way check valve.

The valve is designed to be used with the cap in the open position during diving, 
and really need only be closed in the event of failure. Normal valve travel is ap-
proximately two turns from the closed to fully open position. 

Failure Modes

Kinked Hose

The use of the norprene tubing has drastically reduced the likelihood of a kinked 
hose. The valve is best positioned to avoid sharp bends in the hose routing to 
further reduce the risk of kinking. Use only Halcyon P-Valve hose for any replace-
ments.

Kinked/blocked Condom Catheter

This may occur in the event that the catheter was not properly/completely in-
stalled. Blockages in fl ow may be due to a sharp bend at the end of the catheter, 
or a restriction created by the adhesive within the catheter. Be sure to follow the 
catheter instructions carefully. 

Check Valve Failure

Debris or deposits can build up on the check valves over time and interfere with 
their function. Follow a periodic maintenance and cleaning schedule as recom-
mended in this manual. Replace any worn or damaged check valves.

Maintenance and Cleaning

The Halcyon Streamline P-Valve, like all valves used in scuba diving, should have 
a basic maintenance check on regular intervals. If not cleaned properly, organic 
and inorganic deposits will, over time, reduce the valve’s ability to function 
properly. Additionally, regular cleaning of the Streamline P-Valve is essential in 
preventing bacterial growth that could contribute to a urinary tract infection.

Summary of Contents for Streamline P-Valve

Page 1: ...1 Streamline P Valve Halcyon DIR Dive Systems Installation manual...

Page 2: ...2...

Page 3: ...ing the connection assembly and to reduce the resistance of water pressure The check valve mounted in the Delrin base only allows uid to ow out of the suit preventing water from entering the connectio...

Page 4: ...e process once one overcomes the resistance to putting a hole in your dry or wet suit Carefully choose the area where the valve body will be installed Location is most commonly on the inner thigh It i...

Page 5: ...e the cut into the suit 2 Creating a Hole Halcyon recommends using a professional punch such as a 3 4 grommet punch to create the hole for the valve installation When using a punch place a small lengt...

Page 6: ...la tion All surfaces that will touch the suit are to be glued and should be prepared with a light sanding and then a good cleaning with alcohol This valve is intended to be installed using the supplie...

Page 7: ...none of the Aquaseal areas will rest on the suit while it is drying to the manufacturer s speci cations two hours Once the valve installation is complete and the sealant is dry carefully thread the ex...

Page 8: ...ully open position Failure Modes Kinked Hose The use of the norprene tubing has drastically reduced the likelihood of a kinked hose The valve is best positioned to avoid sharp bends in the hose routin...

Page 9: ...brella valve slip the center stem into the retaining hole in the middle of the valve face Apply gentle pressure to the center of the umbrella valve until it becomes fully seated To inspect or replace...

Page 10: ...URATION TO A PERIOD ENDING ONE YEAR FROM THE DATE OF PURCHASE Some states in the U S and certain foreign countries do not allow limitations on the dura tion of implied warranties so this may not apply...

Page 11: ...11...

Page 12: ...12...

Reviews: