Halcyon Streamline P-Valve Installation Manual Download Page 7

7

ing through the hole in the suit. Apply a small dab of Aquaseal to the threads 
of the nipple with the tip the applicator. 
Screw the outer portion onto the threaded 
nipple until it is tightened against the 
base unit. Using the supplied installation 
wrench, hand-tighten the assemblies to-
gether. Be careful not to over-tighten this 
connection. Position the suit so that none 
of the Aquaseal areas will rest on the suit 
while it is drying to the manufacturer’s 
specifi cations, two hours. 

Once the valve installation is complete 
and the sealant is dry, carefully thread 
the external cap and screw it down until 
snug at the suit shoulder. If you want to 

After  applying  Aquaseal  to  the  base  of  the  valve  (top  left),  work  quickly  to 
position the valve assembly in the desired direction within the suit and then press 
to seal the fabric on the base. Apply Aquaseal to the top seating surface, thread, 
then use the supplied wrench to hand-tighten valve.

Summary of Contents for Streamline P-Valve

Page 1: ...1 Streamline P Valve Halcyon DIR Dive Systems Installation manual...

Page 2: ...2...

Page 3: ...ing the connection assembly and to reduce the resistance of water pressure The check valve mounted in the Delrin base only allows uid to ow out of the suit preventing water from entering the connectio...

Page 4: ...e process once one overcomes the resistance to putting a hole in your dry or wet suit Carefully choose the area where the valve body will be installed Location is most commonly on the inner thigh It i...

Page 5: ...e the cut into the suit 2 Creating a Hole Halcyon recommends using a professional punch such as a 3 4 grommet punch to create the hole for the valve installation When using a punch place a small lengt...

Page 6: ...la tion All surfaces that will touch the suit are to be glued and should be prepared with a light sanding and then a good cleaning with alcohol This valve is intended to be installed using the supplie...

Page 7: ...none of the Aquaseal areas will rest on the suit while it is drying to the manufacturer s speci cations two hours Once the valve installation is complete and the sealant is dry carefully thread the ex...

Page 8: ...ully open position Failure Modes Kinked Hose The use of the norprene tubing has drastically reduced the likelihood of a kinked hose The valve is best positioned to avoid sharp bends in the hose routin...