Halcyon Streamline P-Valve Installation Manual Download Page 3

3

C

ongratulations on your purchase of the Halcyon P-Valve. You can be confi dent 
that every effort has been made to ensure that it will function fl awlessly in 

every diving condition. The Streamline design is the result of several years of 
testing and refi nement; it is the culmination of a design process that draws inspi-
ration from thousands of dives by Halcyon staff, test divers, and explorers around 
the world. 

The Halcyon Streamline P-Valve is a bal-
anced system, machined from a solid piece 
of Delrin®, with a threaded cap that pro-
trudes 5/8” (15 mm) from the surface of 
the suit. The internal and external compo-
nents screw together and are united with 
Aquaseal to ensure watertight reliability.  
The external cap allows individuals to 
vent out of the suit through a condom 
catheter and fl exible tubing, or to easily 
seal off the outside water by turning the 
cap down to seal the captured o-ring, 
preventing water from entering the suit. 
The external cap can be left open during 

the dive for immediate availability, or left 
sealed and only opened prior to use. 

The Halcyon P-Valve’s one-way check valve 

is designed to prevent any water from entering the connection assembly and to 
reduce the resistance of water pressure.   The check valve, mounted in the Delrin 
base, only allows fl uid to fl ow out of the suit, preventing water from entering the 
connection assembly– even if condom attachment has failed. As a fi nal fail-safe, 
should the check valve malfunction the exterior cap can be locked down to seal 
off surrounding water. However, the need to seal the cap is unlikely since the 
connection hardware AND the check valve must fail to allow water into the suit. 
A second check valve in the Delrin base allows gas in the drysuit to equalize with 
air in the connection/catheter assembly. This check valve eliminates the resis-
tance of water pressure while the diver expels, reducing the risk of a connection 
failure. The balanced check valve assembly not only allows for greater redundancy 
and ease of operation, but prevents ambient water from entering the connection/
catheter system. The elimination of ambient water in the connection system is 
particularly benefi cial in cold water or questionable water sources. Additionally, 
the low-pressure design increases the viability of the Streamline valve for use by 
women when paired with an external female catheter.

Extreme exploration dives, such as 
the 14-hour immersion in the Chip’s 
Hole cave system, are made possi-
ble with the Streamline P-valve

Summary of Contents for Streamline P-Valve

Page 1: ...1 Streamline P Valve Halcyon DIR Dive Systems Installation manual...

Page 2: ...2...

Page 3: ...ing the connection assembly and to reduce the resistance of water pressure The check valve mounted in the Delrin base only allows uid to ow out of the suit preventing water from entering the connectio...

Page 4: ...e process once one overcomes the resistance to putting a hole in your dry or wet suit Carefully choose the area where the valve body will be installed Location is most commonly on the inner thigh It i...

Page 5: ...e the cut into the suit 2 Creating a Hole Halcyon recommends using a professional punch such as a 3 4 grommet punch to create the hole for the valve installation When using a punch place a small lengt...

Page 6: ...la tion All surfaces that will touch the suit are to be glued and should be prepared with a light sanding and then a good cleaning with alcohol This valve is intended to be installed using the supplie...

Page 7: ...none of the Aquaseal areas will rest on the suit while it is drying to the manufacturer s speci cations two hours Once the valve installation is complete and the sealant is dry carefully thread the ex...

Page 8: ...ully open position Failure Modes Kinked Hose The use of the norprene tubing has drastically reduced the likelihood of a kinked hose The valve is best positioned to avoid sharp bends in the hose routin...

Page 9: ...brella valve slip the center stem into the retaining hole in the middle of the valve face Apply gentle pressure to the center of the umbrella valve until it becomes fully seated To inspect or replace...

Page 10: ...URATION TO A PERIOD ENDING ONE YEAR FROM THE DATE OF PURCHASE Some states in the U S and certain foreign countries do not allow limitations on the dura tion of implied warranties so this may not apply...

Page 11: ...11...

Page 12: ...12...

Reviews: