Halcyon
Gas Fireplace European
Home
.com
8
SPECIFICATIONS
HALCYON DIRECT VENT GAS FIREPLACE
Model: H50
Serial Number:
____________________________________________________________________________________________________________________________________________________________________________________
VENTED GAS FIREPLACE HEATER – NOT FOR USE WITH SOLID FUEL
This vented gas fi replace heater is not for use with air fi lters.
This vented gas fi replace heater is equipped at the factory for use with natural gas. If conversion
to propane (LP) is desired, the optional factory conversion kit must be used.
This product has been tested and listed by OMNI-Test Laboratories to ANSI Z21.88b-2008 •
CSA 2.33b-2008 Vented Gas Fireplace Heaters, CAN/CGA-2.17-M91, Gas-Fired Appliances for
Use At High Altitudes, and CSA P.4.1-02. This appliance equipped only for altitudes 0-2000 feet
(0-610m) in the USA and 0-4500 feet (1370 m) in Canada without change.
This appliance is only for use with the type of gas indicated on the rating plate and may be
installed in an aftermarket, permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. See the Owner’s Manual for details. This appliance
is not convertible for use with other gases, unless a certifi ed kit is used.
This appliance must be installed in accordance with local codes, if any; if none, follow the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes,
CSA B149.1 This appliance must be properly connected to a venting system in accordance
with the manufacturer’s installation instructions.
Keep burner and control compartment clean. See installation and operating instructions ac-
companying appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to the owner’s information manual provided with this appli-
ance. For assistance or additional information consult a qualifi ed installer, service agency or
the gas supplier.
manufactured by:
EUROPEAN HOME
376 Washington Street
Malden, MA 02148
tel: (781) 324-8383
www.europeanhome.com
Input BTU/hr.:
32,000
Max. Supply Pressure:
7 inches w.c.
Min. Supply Pressure:
4 inches w.c.
Max. Manifold Pressure:
3.2 inch w.c.
Orifi ce Size:
#48 DMS
Electrical Rating: 120V AC, 60 Hz, 1.2 A
Natural Gas H50-01-NG
Input BTU/hr.:
32,000
Max. Supply Pressure:
13 inches w.c.
Min. Supply Pressure:
11 inches w.c.
Max. Manifold Pressure:
9.2 inches w.c.
Orifi ce Size:
#56 DMS
Electrical Rating: 120V AC, 60 Hz, 1.2 A
Propane (LP) Gas H50-01-LP
Report Number: 284-F-06-5
Minimum Clearances to Combustible Materials
Side, Top and Rear Standoff s: 0” (0mm)
Floor Under Unit:
0” (0mm)
Top of Enclosure:
23.25” (591mm)
Door to Right Side Wall:
7” (178mm)
Door to Left Side Wall:
7” (178mm)
Clearances to Combustible Mantel from
Top of Glass Panel Frame
4” Horizontal Mantel: 16” (407mm)
6” Horizontal Mantel: 17.5” (445mm)
8” Horizontal Mantel: 19” (483mm)
10” Horizontal Mantel: 20.5” (521mm)
12” Horizontal Mantel: 22” (559mm)
Rough Opening
Dimensions
Height: 44” (112cm)
Width: 57” (145cm)
Depth: 18.5” (47cm)
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH.
SEVERE BURNS MAY RESULT. KEEP CHILDREN, CLOTHING, FUR-
NITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE
VAPORS AWAY.
CAUTION:
Do not operate the appliance with glass
removed, cracked or broken. Replacement of the panel should
be done by a licensed or qualifi ed service person.
rev.LL.08.11.25