MINIMUM CLEARANCES to COMBUSTIBLES
All of the following limits MUST be maintained in every case:
•
Combustible mantels must be no closer to the top of the glass panel frame than the distances shown in
Figure 12
.
•
Combustible materials must be no closer to the side of the glass panel frame than 7”.
•
The bottom of the Halcyon cabinet may be no closer to the room ceiling than 44”.
•
The minimum height of an enclosure is 57½”.
•
Figure 13
shows the combustible facing limits for the Halcyon Gas Fireplace. Combustible wall facing is not permitted inside
this 653/4” x 44” limit. The 44” dimension is measured from the bottom of the cabinet to the top of the standoff panel and the
653/4” dimension is centered on the cabinet.
•
The wall must be faced with non-combustible material, usually approved cement board. See
What is Non-combustible?
on
page 15.
7”
7”
653/4”
44”
Figure 13 - Facing Clearances