Appendix A - LP Gas Conversion
This appliance was converted on / / to LP gas with kit no. H50-SA-LPCK-01 by
name
addr
which accepts the responsibility that this conversion has been properly made.
Figure A8 - LP Conversion Label Affixed to Burner Assembly
After conversion to use with LP gas, the Halcyon Gas Fireplace has the following specifications:
Propane (LP)
Input:
32,000 BTU/hr. (9.37 kWh)
Manifold Pressure:
9.2” w.c. (2.29 kPa)
Maximum Supply Pressure:
13” w.c. (3.23 kPa)
Minimum Supply Pressure:
11” w.c. (2.73 kPa)
Orifice Size:
#56 DMS
OMNI-Test Laboratories, Inc. has certified that the Halcyon Gas Fireplace meets the
ANSI Z21.88-2007 • CSA 2.33-2007 Vented Gas
Fireplace Heaters
and
CAN/CGA-2.17-M91, Gas-Fired Appliances for Use At High Altitudes
standards.
The Halcyon Gas Fireplace is approved for installation at elevations up to 2000 feet in the U.S. and 1370 meters (4500 feet)
in Canada without change. If your installation is at an elevation greater than these, consult with the local authority having
jurisdiction for gas product installations to determine their specific requirements for high altitude installations.
When properly installed and operating the flames in the Halcyon Gas Fireplace look like those in
Figure A9.
Figure A9- Halcyon Flames