H
I
Figure 11 - Terminal Clearances
Clearance
U.S. Minimum
1
Canadian Minimum
2
A - Clearance above the grade, a veranda, porch, deck, or balcony.
12 in. (30 cm)
12 in. (30 cm)
B - Clearance to window or door that may be opened.
12 in. (30 cm)
12 in. (30 cm)
C - Clearance to permanently closed window.
See Note 3
See Notes 3 and 4
D - Vertical clearance to ventilated soffit located above the terminal
within a horizontal distance of 2 ft. (61 cm) from the center line of
the terminal.
See Note 3
See Notes 3 and 4
E - Clearance to an unventilated soffit.
See Note 3
See Notes 3 and 4
F - Clearance to an outside corner.
See Note 3
See Notes 3 and 4
G - Clearance to an inside corner.
See Note 3
See Notes 3 and 4
H - Clearance to each side of centerline of gas meter/regulator as-
sembly.
See Note 3
3 ft. (91 cm) within a height
of 15 ft. (4.5 m) above the
meter/regulator assembly
I - Clearance to a service regulator vent outlet.
See Note 3
3 ft. (91 cm)
J - Clearance to non-mechanical air supply inlet into building or the
combustion air inlet to any other appliance.
9 in. (23 cm)
12 in. (30 cm.)
K - Clearance to mechanical air supply inlet.
3 ft. (91 cm) above if within
10 ft. (3 m) horizontally
6 ft. (1.83 m)
L - Clearance above a paved sidewalk or paved driveway located on
public property.
See Note 3
7 ft. (2.12 m)
M - Clearance under veranda, porch, deck or balcony.
See Note 3
12 in. (30 cm)
See Note 5
Notes:
1 - In conformance with the current National Fuel Gas Code, ANSI Z223.1
2 - In conformance with the current CAN/CGA B149 Gas Installation Code
3 - Clearance is accordance with local installation codes and the requirements of the gas supplier
4 - Degagement conforme aux codes d’installation locaux et aux exigences du fournisseur de gaz.
5 - Permitted ONLY if veranda, porch, deck or balcony is fully open on a minimum of two sides below the floor.
PRE-INSTALLATION PLANNING
Table 5 - Minimum Terminal Clearances
Vent terminals shall not be
recessed into a wall or siding.
Note