Inserting the charged battery
1. Align the battery changing rack with the charged battery at right angles to
the machine using the lift truck fully raised to 200 mm.
2. Repeat steps 7 and 8 in section
Removing the discharged battery
.
3. Operate the foot lever
Fig. 67-5
on the battery changing rack to unlock the
battery and push the battery fully into the machine.
4. Close the manually operated locking device of the battery in the machine.
To do this, raise the locking device and swivel it in the direction of the
battery
Fig. 67-9
.
5. Raise the battery changing rack fully using the lift truck.
The automatic locking device of the battery in the machine is closed.
6. Remove the battery changing rack from the machine.
7. Plug the machine plug into the battery socket.
8. Fold back the seat console.
9. Close and lock the right side door.