Scrubmaster B400 R (7190)
117
Maintenance and servicing
Changing the battery standard
1. Park the machine on a level surface, turn it off and remove the key.
2. Release the locking device on the right side door of the machine and then
open the side door.
3. Open the seat console all the way.
4. Remove the machine plug.
5. Hook the machine plug into the seat console
Fig. 34-5
.
6. Hook the lifting gear of the battery changing cross-beam into the eyelets of
the battery trough
Fig. 36-1
.
The lifting gear must carry out a vertical pull so that the battery trough is not
distorted.
7. Slowly lift the battery trough upwards and swivel out to the side.
8. Place the battery trough on a level surface.
9. Modify the clamp if necessary, see section
Modifying the clamp
.
10.To fit the battery, follow the instructions in the reverse order.
1
Eyelets for crane gear
2
Connection diagram
Note
Please ensure that the battery trough is in the correct installation
position! See connecting diagram
Fig. 36-2
.
Note
Information on handling the battery changing system, see
section 6.7
Battery changing system
on page 157.
Fig. 36
Driving direction
2
1
1