Citytrac 4200
Citymaster 1200
Citycleaner
Service Documents
For internal use only
Status
March 2009
Page
65 of 108
Circulation off,
Work hydraulics on
(Y6 and at least one consumer connected)
195 bar
STEERING
SIDE BRUSH
MOTOR
FRONT ATTACHMENT
MOTOR
PIVOTING
CONTAINER
EMPTYING
FAN
MOTOR
To feed
circuit
Pressure control valve opens
at 195 bar, cause of oil from
interchange valve 8
Y6 energised, work hydraulics on
Y9 energised
Schematic shows old version