Ultrasonic Antifouling Smart 2 lite
En / Installation manual
Ver. 02/2020
Please read and follow the installation manual carefully! In order for the device to work
properly it has to be installed correctly, especially the ultrasonic transducers.
Package Contents
- main box Smart 2 lite
- 2 transducers with connectors IP68
- Transducer mounting adapters
- 8 m cable for each transducer
- 4 m cable for DC connection
- abrasive paper
- cleaning alcohol wipe
- 2 k adhesive
- contact grease
- user manual
Introduction
Ultrasound is mainly used in industry, medicine, for cleaning purposes… Our device works on the
principle of converting electrical energy into mechanical energy through a transducer. The transducer
transmits ultrasonic vibrations that resonate through the hull of the boat and thus prevents the formation
of biofilm on the hull. Ultrasonic vibrations also create a cavitation effect below the water surface. The
cavitation effect destroys the cells of microorganisms and stops them from adhering to the underwater
part of the hull. Microorganisms and biofilm are food for algae and seashells that adhere to the hull and
underwater parts of a boat, such as rudder, propeller…
Ultrasonic antifouling is environmentally friendly.
Follow the instruction manual and thus correctly install the device. The hull of the boat and underwater
parts of the boat will stay clean for a few seasons. Underwater anodes can be replaced during a lift-out
or in the water.
Warning
Install the ultrasonic device on the boat after cleaning the hull thoroughly and applying the antifouling
paint. Device will prevent the growth of organisms and partly clean the hull. Place the device on the
inside of the boat.
Device is suitable for plastic and metallic hulls (aluminum, iron).
Technical Specifications
- Main box (IP55)
- 2 Transducers 60W (IP68)
- DC 12V or 24V
- Frequency range 20-55khz
- 2 Transducer resonate band
- Power adjustable 4 steps
- Burst time adjustable 2 steps
- Burst pause time adjustable 2 steps
- Average consumption 250mA - 1A
- Output Transducer voltage max. 300V (1000Vpp)
- Low voltage protection