Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
1. SAFETY INSTRUCTIONS
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
I N S T R U C T I O N S F O R :
SPRAY GUN CLEANER
MODEL NO:
SM23/2.V3
WARNING! Ensure Health & Safety, local authority, general workshop practice regulations are adhered to when using equipment.
WARNING! Installation site must be equipped with suitable fire extinguishers (water must not be used) and escape routes.
WARNING! Disconnect the air supply from the tank before changing accessories, servicing or performing any maintenance.
Maintain the tank in good condition (use an authorised service agent).
Replace or repair damaged parts. Use genuine parts only. Non-authorised parts may be dangerous and will invalidate the warranty.
Locate the tank in an adequate working area. Ensure the tank stands on a firm level surface. Keep area clean and tidy and free from
unrelated materials. Ensure the area is well ventilated and has adequate lighting.
WARNING! Ensure correct air pressure is maintained and not exceeded. Recommended pressure (20 - 50psi).
Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use, and ensure that all connections are secure.
Use only water or recommended solvents as a cleaning agent, do not pour any other type of cleaning fluid into the tank.
Keep the tank clean. Remove and clean the suction filter regularly for best performance.
WARNING! DO NOT SMOKE and keep sources of ignition, such as heaters, lamps, etc. away from the unit, together with
flammable or combustible materials, as there is an explosion risk when solvents are used for cleaning.
WARNING! Wear approved safety eye protection, mask and gloves. If solvent gets on skin or in eyes wash thoroughly with water
and take any other action as required by the solvent instructions.
Remove ill fitting clothing, ties, watches, rings and other loose jewellery, contain long hair, and wear appropriate protective clothing.
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
Keep non-essential persons away from the working area.
In case of fire in tank, do not attempt to move the unit or remove spray guns.
DO NOT
use the tank with the lid open and
DO NOT
use it for spray gun testing.
DO NOT
use the tank for any purpose other than for which it is designed.
DO NOT
operate the tank if any parts are missing or damaged as this may cause failure and/or possible personal injury.
DO NOT
over-fill the tank.
DO NOT
direct air from the air hose at yourself or others.
DO NOT
operate the tank when you are tired or under the influence of alcohol, drugs or intoxicating medication.
When cleaning is complete, ensure all controls are in the ‘off’ position and that the air supply is turned off.
WARNING! It is operator’s responsibility to ensure that there is no uncontrolled discharge of any fluids used with this unit and
that appropriate arrangements have been made for correct disposal of waste in accordance with government/local authority
regulations.
SM23/2.V3 Issue No.1 - 20/10/09
SPECIFICATION:
. . . . . . . . . . . . . . . . . . . . . . . . . .
Cleans . . . . . . . . . . . . . . . . . . . . . . . . . . 2 pots + 2 guns
Operating pressure . . . . . . . . . . . . . . . . . . 20-50 psi
Width x depth x height . . . . . . . . 470 x 572 x 1300mm
Air consumption. . . . . . . . . . . . . . . . . . . . . . 2-4 cfm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30kg
2. INTRODUCTION & SPECIFICATION
Fully automatic operation - close lid to start and open lid to stop. Corrosion resistant tank suitable for containing water and detergent necessary
for cleaning water based spray guns. Powerful and reliable piston pump system washes up to two guns simultaneously.
NOTE:
The air supply for the SM23/2 must be equipped with a regulator, filter/separator and oiler in order to ensure safe operation and to
prolong the life of the product.
These items are not supplied and must be purchased separately.
Consult your local Sealey dealer for a
suitable product.
For recommended hook-up, see diagram below.
4.1.
Ensure that the air valve (20) is closed before connecting the air supply.
4.2.
An air pressure of 20-50psi, and an available air volume of 2-4cfm will be required to operate the unit.
WARNING!
Ensure air supply is clean and does not exceed 50psi (3.5 bar). Too high an air pressure and/or unclean air will
shorten the product life due to excessive wear, and may be dangerous, causing possible damage and personal injury.
4.3.
Drain the air supply tank daily. Water in the air line will damage the unit.
4.4.
Clean the air supply filter weekly.
4.5.
Line pressure should be increased to compensate for unusually long air
hoses (over 8 metres). The minimum hose internal diameter should be
10mm and fittings must have the same internal dimension.
4.6.
Keep hose away from heat, oil and sharp edges. Check hoses
for wear, and make certain that all connections are secure.
4.7.
The air inlet connection is 1/4”BSP.
4. AIR SUPPLY
HOOK-UP
3. ASSEMBLY
Note:
Item numbers in brackets are those in the attached Parts Diagram. Instructions should be read in conjunction with this diagram.
3.1.
Attach legs to cabinet with screws (63), washers (64) and nuts (65) provided and fit drain valve (66) to base of tank (2).
3.2.
To prevent possible static build up, run an earth wire from the frame to a suitable earth.
Original Language Version