Do not wind the cable because of the coil effect!
For the laying of the transducer cable we recommend the use self extinguishing rigid conduit.
The cable surge can be cut. If it is too short, it can be extended with a protective box. Max lenght up to
12m.
Main Box installation
The best position for the generator is near the battery you attempt to plug into. The cable for battery
connection is 4 meters long. The position of the installation depends on the length of the cables of
transducers and generator.
Make sure that the switch is in the OFF position.
Remove the lid from the main box and fix it with screws on the wall or any other convenient place. We
suggest you place the generator in a room with other electrical devices. Run the cable of the transducer
through the cable thread of the generator and connect it to the connectors (1). Polarity is not important.
Fasten the cable threads.
Connect the supply cable to the connector (2) and directly to the 12V or 24V battery.
First connect the + pole, then the - pole!
Set the DIP switch (3) according to your needs. Settings on last page.