Foil 108
10. Error Table With Information
On Service Display
Error code in
Malfunction
Remark
the display
4.5.2.2.
CAN operator panel
Check CAN bus to Cleaning agent/SWA
Code B not recognised operator panel; check contacts and
(for Cleaning agent/
connectors; check resistance (120
W
);
SWA) 1); 5)
check module coding (see chapter 7)
(60
W
due to parallel connection)
4.5.3.1.
CAN operator panel
Check CAN bus to pre-sweeper/side
Code A no response; brush operator panel; check contacts and
timeout
connectors; check resistance (120
W
);
(for pre-sweeper /
check voltage supply of operator panel
side brush)
(voltage transformer)
1); 5)
(60
W
due to parallel connection)