background image

OPERATION

Press the        button once.

Press the        button once.

Press the        or        button.

UP

DOWN

3. Enter the TENS digit

• Press the 

 or 

 button to select the

desired  value  for  the  TENS  digit.  Any
value from 0 to 9 can be selected. When
the desired value is displayed, press the

  button.  The  UNITS  digit  begins  to

flash.

4. Enter the UNITS digit

• Use  the 

  or 

  button  to  select  the

desired  value  for  the  UNITS  digit.  Any
value from 0 to 9 can be selected. When
the desired value is displayed, press the

 button. This will store the temperature

setting  in  memory  and  display  the  tem-
perature  setting.  Heater  control  begins.
Remove the card to lock the data.

NOTE:

If  the  power  switch  is  turned  off,  or  power  is  lost
during the execution of this procedure, no data will
be entered. The entire procedure must be repeated
from step 1.

When the station is ON ( ) and
the card is in the station, the data
entry procedure follows:

1. Hold  the 

  button  down  for  at  least  one

second.

2. The  current  temperature  setting  will  be

displayed, then the HUNDREDS digit will begin
to  flash.  This  indicates  that  the  station  has
entered the temperature setting mode.

3. Continue with the procedure of 2-4 above.

7

Summary of Contents for 472D

Page 1: ...ore using it Leaving the screw in place will cause serious problems Be sure to SAVE THIS SCREW REPLACE the pump securing screw M4 25 red into the bottom of the 472D station before transporting it Leav...

Page 2: ...Spring filter Ceramic paper filter S Ceramic paper filter L Cleaning pin for 1 0 mm 0 04 in nozzle Cleaning pin for heating element Filter pipe Station Iron holder Control card Card chain SPECIFICATI...

Page 3: ...ith the following precautions Do not touch the metallic parts near the nozzle nearby plastic parts and the iron holder Do not use the product near flammable items Advise other people in the work area...

Page 4: ...pipe Inside housing Cord assembly POWER VACUUM Heater lamp Power switch Receptacle Membrane sheet Vacuum outlet cap IRON UP DOWN Fuse holder CAL POT CAL Power cord Temperature display Control card sl...

Page 5: ...Set the iron in the iron holder Figure 5 5 Plug the power cord into the power supply and turn the power switch to ON CAUTION Be sure the power switch is OFF before connecting the desoldering iron cor...

Page 6: ...cleaner is not included 3 Melt the solder Apply the nozzle to the soldered part and melt the solder NOTE Never allow the nozzle to touch the board itself Confirm that the solder is melted NOTE To con...

Page 7: ...D will operate normally with the card inserted Remove the control card to lock the data Setting Changing the temperature 1 Insert the card into the card slot in the front panel of the station The HUND...

Page 8: ...e button This will store the temperature setting in memory and display the tem perature setting Heater control begins Remove the card to lock the data NOTE If the power switch is turned off or power i...

Page 9: ...emperature tolerance Flashing of the temperature display When the station enters the Low temperature tolerance setting mode the HUNDREDS digit will begin flashing Enter and store the value in the same...

Page 10: ...ace and inside hole of the nozzle If it is slightly worn recoat the tip with fresh solder If it is worn or eroded or the inside diameter seems unusually wide replace the nozzle NOTE The inside hole an...

Page 11: ...le the filter case CAUTION Insert the small ceramic paper filter into the filter retainer at the station Using the large ceramic paper filter may damage the unit or reduce the effectiveness of the uni...

Page 12: ...N If the fixing plate is difficult to remove apply hot air to it to warm it up Never use excessive force to remove the plate as it is easy to bend and a bent plate will allow a leak which reduces the...

Page 13: ...ter and put the back holder into the filter pipe 6 Insert the filter pipe into the main body and secure it by turning the back holder knob clockwise Replacing the heating element Check the resistance...

Page 14: ...older the heating element leads red wires H sensor leads white wires S 13 Reassemble the unit Recalibrate the temperature a Set the desire temperature b Adjust the temperature calibration pot CAL unti...

Page 15: ...zzle temperature goes below the heater error temperature tolerance setting the temperature display will flash This indicates the possibility of a heater malfunction EXAMPLE Assume the temperature sett...

Page 16: ...04 in 2 5 mm 0 1 in A1006 1 3 mm 0 05 in 3 0 mm 0 12 in A1007 1 6 mm 0 06 in 3 0 mm 0 12 in A1396 2 3 mm 0 09 in 3 8 mm 0 15 in Part No A B A1394 1 0 mm 0 04 in 2 1 mm 0 083 in Cleaning Pin Drill Par...

Page 17: ...nt cover 3 A1174 Heating element 4 B1015 Nut 5 B1654 Flange 6 A1304 Front holder Set of 10 7 A1030 Spring filter 8 B1655 Button With switch 9 B1656 Board 10 B1916 Filter pipe Set of 10 11 A1033 Cerami...

Page 18: ...B2068 B2725 B2729 B1053 B1312 B2506 B1057 B2060 B2059 B2058 A1013 B2085 B1056 A1014 B1050 B1059 B1313 Part Name Vacuum outlet cap Ceramic paper filter S Filter retainer O ring Vacuum outlet retainer F...

Page 19: ...4 1 3 1 3 1 4 1 5 2 3 4 HEAD OFFICE 4 5 SHIOKUSA 2 CHOME NANIWA KU OSAKA 556 0024 JAPAN TEL 81 6 6561 3225 FAX 81 6 6561 8466 http www hakko com AMERICAN HAKKO PRODUCTS INC 28920 N AVENUE WILLIAMS VAL...

Reviews: