background image

 

Cordless suction pick-up tool 

 Ultra-compact high powered pump eliminates need for a power cord and an air 

tube. 

 Continuous suction allows easy handling of objects. 
 Soft touch switch 
 Pen-type body is easy to fit into your hand. 
 Utilizes antistatic material 
 Nozzle with a stopper 

· The stopper prevents the nozzle nib from shooting through the pad, damaging 
components, and causing suction failures. 

 

 Intended works 

Semiconductor-related works 
Pick-up of SMDs 
Surface mount PCB assembly 
Conveyance of ICs  

 

 

  The pick-up tool is designed to suck up micro components used for PCBs, 

etc. and not to absorb dust. If used to absorb dust, it may become inoperable 
due to the clogging of filters mounted inside. 

 

  Specifications of pad 

Material 

Electrically conductive silicone rubber 

Heatproof 
temperature 

Approximately 150

°C

 

Resistance value 

10

4

 to 10

6

 

Indication of pad 
replacement 

When any crack or tear is found during a visual check, 
or objects cannot be sucked up effeciently 

 

 

 Nozzle Single Use 

Nozzle 

Part 

Name/Descripation  Shape 

Stamped* 

Applications 

Summary of Contents for 394-01

Page 1: ...o batteries nozzle pad Service life of battery Pickup repetition limit 1 Continuous pickup time 2 Approx 30 000 pickup times With alkaline batteries Approx 15 hours 1 26 mm x 26 mm QFP is pickup for...

Page 2: ...ctor related works Pick up of SMDs Surface mount PCB assembly Conveyance of ICs The pick up tool is designed to suck up micro components used for PCBs etc and not to absorb dust If used to absorb dust...

Page 3: ...chip Only these 2 shapes are avilable for single use Use Nozzle with Pad Nozzle Part No A1165 A1486 Name Description Bent nozzle 1 1mm Straight nozzle 1 1mm Outside Diameter 1 65mm 1 65mm Figure Pad P...

Page 4: ...will not be flicked and lost For the HAKKO 394 a very fine bent nozzle with 0 26mm hole diameter A1198 which can be used for 0603 sized components is available The nozzle ensures safe pick up operati...

Page 5: ...A1165 Bent nozzle w stopper 1 1mm A1312 Pad 5mm A1311 Pad 10mm A1164 Bent nozzle 0 4mm A1198 Bent nozzle 0 26mm A1486 Straight nozzle w stopper 1 1mm A1166 Pad 3mm A1167 Pad 7mm B2690 Joint w filter B...

Page 6: ...then check that the suction force is sufficient If the suction force is not recovered even after replacement of batteries overhaul the unit according to the following procedures 1 Remove the bent noz...

Page 7: ...addition clean the inside of the joint and silicon tube If cracks breaks etc are observed in the joint or silicon tube Replace the joint and silicon tube with new ones HAKKO 394 Replacement Parts 6 R...

Page 8: ...7 Press fit the silicon tube fully into the joint and pump to the end Refer to Photos 9 and 10...

Page 9: ...er to Photo 1 If the suction force is not recovered even after overhauling it can be assumed that the pump has deteriorated In this case it is recommended to send the unit in for repair Send it to the...

Reviews: