LIST OF COMPONENTS

Decking unit light hatch   

 

2500x600 AL 

4071253

 

19.5

Load class 3 (2.0 kN/m

2

3050x600 AL 

4071305

                      24.5

 

 

  

 

  

Ladder

 

ST 2100 AL 

2091210

 3.4

For decking unit with hatch

Decking unit light W=600 mm

 700x600 

4071072

 6.6 

Load class 3 (2.0 kN/m

2

) 1050x600 

4071102

 9.1

 1250x600 

4071122

 10.6

 

1550x600 

4071152

 

12.8

 

1655x600 

4071162

 

13.5

 1964x600 

4071192

 15.8

 2050x600 

4071202

 16.4

 

2500x600 

4071252

 19.6 

 

2550x600 

4071257

 20.0

 3050x600 

4071302

 24.6

Name 

Code 

Item No. 

Weight

Decking unit light hatch and ladder  

 

3050x600 AL 

4071306

 25.0

Load class 3 (2.0 kN/m

2

)

AL plank  W=200 mm

 

ALP 770x200x90 

2153079

 3.6

L=770-2500 - Load class 6 (6.0 kN/m

2

ALP 1050x200x90 

2153105

 4.5

L=3050 - Load class 5 (4.5 kN/m

2

ALP 1250x200x90 

2153125

 

5.0

 

ALP 1655x200x90 

2153165

 

6.2

 

ALP 1964x200x90 

2153195

 7.1

 

ALP 2500x200x90 

2153255

 8.7 

 

ALP 3050x200x90 

2153305

 10.3

Summary of Contents for UNIVERSAL ALUMINIUM S4

Page 1: ...ALUMINIUM USER S MANUAL HAKI UNIVERSAL S4 HAKI AB 2019...

Page 2: ...ddition of scaffold tubes and approved couplers to the scaffold Adding components from different suppliers may invalidate the insurance cover HAKI reserves the right to make technical modifications on...

Page 3: ...ply in accordance with the user s manual for this system In addition HAKI Universal steel standards may be used for example in the base of the scaffolding when loads on standards are high or when cons...

Page 4: ...5 kN m General data HAKI Universal Aluminium is erected with bay widths of 700 770 1050 1250 or 1655 mm and normally with a bay length of 3050 mm and 2 0 m between lifts LB or ERB beams can be used b...

Page 5: ...2000 4017206 5 2 S4 3000 4017306 7 7 Ledger beam LB LB 350 AL 4021031 1 9 With spring locking catch LB 770 AL 4021073 2 9 34 mm LB 1050 AL 4021101 3 5 LB 1250 AL 4021121 4 2 LB 1655 AL 4021161 4 8 LB...

Page 6: ...S 1250 AL 4122120 4 5 DS 1655 AL 4122160 4 9 DS 1964 AL 4122190 5 4 DS 2500 AL 4122245 6 1 DS 3050 AL 4122300 6 7 Wall tie VST 1000 7111100 5 3 With flexible plate VST 2000 7111200 9 1 48 mm VST 3000...

Page 7: ...5x600 4071162 13 5 1964x600 4071192 15 8 2050x600 4071202 16 4 2500x600 4071252 19 6 2550x600 4071257 20 0 3050x600 4071302 24 6 Name Code Item No Weight Decking unit light hatch and ladder 3050x600 A...

Page 8: ...x90 2153124 6 1 L 3050 load class 4 3 0 kN m2 ALP 1655x295x90 2153164 7 5 ALP 1964x295x90 2153194 8 6 ALP 2500x295x90 2153254 10 5 ALP 3050x295x90 2153304 12 4 AL plank W 230 mm ALP 770x230x90 2158077...

Page 9: ...AL 4058245 9 2 Guardrail post SRS 1000 7015001 7 3 Steel For erection on ledger beam LB Guardrail post SSKS 23 mm 7015005 6 1 Steel SSKS 22 mm 7015006 6 1 Jaw width 23 mm or 22 mm For erection on sin...

Page 10: ...designed to provide access to the upper decks from the inside of the scaffold 10 If the scaffold is to be used outdoors erection or dismantling work must be discontinued if the weather conditions are...

Page 11: ...g the scaffold at a level of 1 0 m Guardrail frames must be fitted in each bay and at each lift level on the outside of the scaffold Alternatively fit the vertical diagonal braces Continue erecting th...

Page 12: ...ls and toeboards Don t forget to lock the beams and decking Anchor the scaffold at a height of approximately 4 8 m using tie rods and clamps Check that the fixings in the facade can carry the forces i...

Page 13: ...ails replace the ledger beams 8 Fit the hooks of the UTV stairway over the tubes of the transom beams and lock the stairs using the locking device Fit the handrail at the 1 0 m level and provide the t...

Page 14: ...king These are available in all bay sizes and with widths of 400 and 600 mm Alternatively HAKI aluminium planks may be used These units are available in all bay sizes and with widths of 170 200 230 29...

Page 15: ...the scaffold always be anchored as high up as possible Where there are brackets the scaffold must be anchored at the level of the brackets Scaffold with lattice beams must be anchored at the fixing p...

Page 16: ...e jack max Base jack min Vertically braced using SKRD 2 0 2 0 4 0 16 4 9 5 20 9 9 8 16 4 9 5 The support surface must be capable of withstanding a design load per standard of twice the relevant permit...

Page 17: ...102 84 36 94 72 32 88 64 28 76 46 22 60 22 12 770 1 5 All 100 82 34 90 68 28 84 58 26 72 40 20 54 14 10 1050 1 5 All 94 70 26 82 52 22 74 40 18 58 14 10 1250 1 5 All 90 64 24 76 42 16 66 26 12 Permiss...

Page 18: ...r unilateral loading Wide scaffold Facade scaffold Loaded beam Loaded beam Ledger beam LB AL a m 700 770 1050 1250 1655 1964 2500 3050 LB 350 6 6 6 6 6 6 6 6 LB 770 6 6 6 6 6 6 6 6 LB 1050 6 6 6 6 6 6...

Page 19: ...6 LB 770 6 6 6 6 6 6 5 5 LB 1050 6 6 6 6 5 5 4 4 LB 1250 6 6 6 6 5 5 4 3 LB 1655 6 6 5 5 4 4 3 3 LB 1964 6 6 5 5 4 4 3 3 LB 2500 5 5 4 4 3 3 3 3 LB 3050 5 5 4 3 3 3 2 Single tube beam ERB AL a m 564...

Page 20: ...564 AL SK 770 AL SK 1250 AL 6 4 3 3 3 Beam type Permissible load q kN m Permissible distributed load Q kN Permissible centrepoint loads P kN Permissible point loads P3 kN Permissible point loads P4 kN...

Page 21: ...l HAKI Stair Tower Ascent via ladders may be arranged by means of HAKI decking units with trapdoors and ladders or HAKI STV ladders Lattice beams Lattice beams of aluminium Aluminium lattice beams are...

Page 22: ...he material must be stacked up high suitable racking and shelves should be used 5 Wooden and plastic components e g platforms toe boards toe board holders etc should be stored in a sheltered area so a...

Page 23: ...with lift heights of 2 0 m using 3 0 m standards internally and 2 0 m standards externally In order to be able to fit guardrails prior to decking using HAKI s advance guardrail tool or with the aid o...

Page 24: ...e scrapped and replaced by new material Around a standard between two lifts or around the lower tube in a ledger beam LB AL fitted between two standards PLEASE NOTE It is not permissible to attach aro...

Page 25: ...25 Notes...

Page 26: ...26 Notes...

Page 27: ...27 Notes...

Page 28: ...tance to wall or similar as short as possible 3 Scaffold aligned correctly horizontally and vertically 4 Components correctly fi tted and locked 5 Bracing correctly fi tted 6 Anchoring with right numb...

Reviews: