background image

6

LIST OF COMPONENTS

Guardrail frame SKRD  

 

SKRD    700 AL 

4052066

 

3.3

With spring locking catch 

SKRD    770 AL 

4052073

 

3.5

 

SKRD 1050 AL 

4052101

 4.5 

 

SKRD 1250 AL 

4052121

 4.8

 

SKRD 1655 AL 

4052161

 5.9

 

SKRD 1964 AL 

4052191

 6.6

 

SKRD 2500 AL 

4052246

 7.8 

 

SKRD 3050 AL 

4052301

 8.9

Plane brace  

 

HDS 3050x1655 AL 

4141000

 7.0 

 

HDS 3050x1250 AL 

4141001

 6.5 

 

HDS 2500x1250 AL 

4141005

 6.0 

 

HDS 2500x1655 AL 

4141006

 

6.3

Plan brace telescopic  

 

HDS AL 

4141010

 

6.3

Tie rod tube AL

 

SVF 450x48 AL 

4832045

 1.2

Tube diameter 48 mm

Permissible load 5.4 kN

Erected with coupler 48x48

Diagonalbrace  

 

DS 1250 AL 

4122120

 4.5 

 

DS 1655 AL 

4122160

 4.9 

 

DS 1964 AL 

4122190

 5.4 

 

DS 2500 AL 

4122245

 

6.1

 

DS 3050 AL 

4122300

 

6.7

Wall tie  

 

VST 1000 

7111100

 5.3

With flexible plate 

VST 2000 

7111200

 

9.1

Ø 48 mm 

VST 3000 

7111300

 13.7 

Erected with right angle coupler 48x48 

VST 4000 

7111400

 16.7

 

VST 5000 

7111500

 21.9

 

VST 6000 

7111600

 24.5

Name 

Code 

Item No. 

Weight

Decking unit light W=400 mm

 1050x400 

4073102

 7.1

Load class 3 (2.0 kN/m

2

) 1250x400 

4073122

 8.5

 

1550x400 

4073152

 

10.0

 

1655x400 

4073162

 

10.5

 1964x400 

4073192

 12.0

 2050x400 

4073202

 12.4

 

2500x400 

4073252

 15.1 

 

2550x400 

4073257

 16.5

 3050x400 

4073302

 18.5

Tie rod tube  

 

SVF 450X48 

8832046

 2.2

Ø 48 mm 

SVF 600x48 

8832061

 2.6

Permissible load 9 kN 

SVF 900X48 

8832091

 

3.7

Erected with right angle coupler 48x48 

SVF 1200X48 

8832121

 4.8

Summary of Contents for UNIVERSAL ALUMINIUM S4

Page 1: ...ALUMINIUM USER S MANUAL HAKI UNIVERSAL S4 HAKI AB 2019...

Page 2: ...ddition of scaffold tubes and approved couplers to the scaffold Adding components from different suppliers may invalidate the insurance cover HAKI reserves the right to make technical modifications on...

Page 3: ...ply in accordance with the user s manual for this system In addition HAKI Universal steel standards may be used for example in the base of the scaffolding when loads on standards are high or when cons...

Page 4: ...5 kN m General data HAKI Universal Aluminium is erected with bay widths of 700 770 1050 1250 or 1655 mm and normally with a bay length of 3050 mm and 2 0 m between lifts LB or ERB beams can be used b...

Page 5: ...2000 4017206 5 2 S4 3000 4017306 7 7 Ledger beam LB LB 350 AL 4021031 1 9 With spring locking catch LB 770 AL 4021073 2 9 34 mm LB 1050 AL 4021101 3 5 LB 1250 AL 4021121 4 2 LB 1655 AL 4021161 4 8 LB...

Page 6: ...S 1250 AL 4122120 4 5 DS 1655 AL 4122160 4 9 DS 1964 AL 4122190 5 4 DS 2500 AL 4122245 6 1 DS 3050 AL 4122300 6 7 Wall tie VST 1000 7111100 5 3 With flexible plate VST 2000 7111200 9 1 48 mm VST 3000...

Page 7: ...5x600 4071162 13 5 1964x600 4071192 15 8 2050x600 4071202 16 4 2500x600 4071252 19 6 2550x600 4071257 20 0 3050x600 4071302 24 6 Name Code Item No Weight Decking unit light hatch and ladder 3050x600 A...

Page 8: ...x90 2153124 6 1 L 3050 load class 4 3 0 kN m2 ALP 1655x295x90 2153164 7 5 ALP 1964x295x90 2153194 8 6 ALP 2500x295x90 2153254 10 5 ALP 3050x295x90 2153304 12 4 AL plank W 230 mm ALP 770x230x90 2158077...

Page 9: ...AL 4058245 9 2 Guardrail post SRS 1000 7015001 7 3 Steel For erection on ledger beam LB Guardrail post SSKS 23 mm 7015005 6 1 Steel SSKS 22 mm 7015006 6 1 Jaw width 23 mm or 22 mm For erection on sin...

Page 10: ...designed to provide access to the upper decks from the inside of the scaffold 10 If the scaffold is to be used outdoors erection or dismantling work must be discontinued if the weather conditions are...

Page 11: ...g the scaffold at a level of 1 0 m Guardrail frames must be fitted in each bay and at each lift level on the outside of the scaffold Alternatively fit the vertical diagonal braces Continue erecting th...

Page 12: ...ls and toeboards Don t forget to lock the beams and decking Anchor the scaffold at a height of approximately 4 8 m using tie rods and clamps Check that the fixings in the facade can carry the forces i...

Page 13: ...ails replace the ledger beams 8 Fit the hooks of the UTV stairway over the tubes of the transom beams and lock the stairs using the locking device Fit the handrail at the 1 0 m level and provide the t...

Page 14: ...king These are available in all bay sizes and with widths of 400 and 600 mm Alternatively HAKI aluminium planks may be used These units are available in all bay sizes and with widths of 170 200 230 29...

Page 15: ...the scaffold always be anchored as high up as possible Where there are brackets the scaffold must be anchored at the level of the brackets Scaffold with lattice beams must be anchored at the fixing p...

Page 16: ...e jack max Base jack min Vertically braced using SKRD 2 0 2 0 4 0 16 4 9 5 20 9 9 8 16 4 9 5 The support surface must be capable of withstanding a design load per standard of twice the relevant permit...

Page 17: ...102 84 36 94 72 32 88 64 28 76 46 22 60 22 12 770 1 5 All 100 82 34 90 68 28 84 58 26 72 40 20 54 14 10 1050 1 5 All 94 70 26 82 52 22 74 40 18 58 14 10 1250 1 5 All 90 64 24 76 42 16 66 26 12 Permiss...

Page 18: ...r unilateral loading Wide scaffold Facade scaffold Loaded beam Loaded beam Ledger beam LB AL a m 700 770 1050 1250 1655 1964 2500 3050 LB 350 6 6 6 6 6 6 6 6 LB 770 6 6 6 6 6 6 6 6 LB 1050 6 6 6 6 6 6...

Page 19: ...6 LB 770 6 6 6 6 6 6 5 5 LB 1050 6 6 6 6 5 5 4 4 LB 1250 6 6 6 6 5 5 4 3 LB 1655 6 6 5 5 4 4 3 3 LB 1964 6 6 5 5 4 4 3 3 LB 2500 5 5 4 4 3 3 3 3 LB 3050 5 5 4 3 3 3 2 Single tube beam ERB AL a m 564...

Page 20: ...564 AL SK 770 AL SK 1250 AL 6 4 3 3 3 Beam type Permissible load q kN m Permissible distributed load Q kN Permissible centrepoint loads P kN Permissible point loads P3 kN Permissible point loads P4 kN...

Page 21: ...l HAKI Stair Tower Ascent via ladders may be arranged by means of HAKI decking units with trapdoors and ladders or HAKI STV ladders Lattice beams Lattice beams of aluminium Aluminium lattice beams are...

Page 22: ...he material must be stacked up high suitable racking and shelves should be used 5 Wooden and plastic components e g platforms toe boards toe board holders etc should be stored in a sheltered area so a...

Page 23: ...with lift heights of 2 0 m using 3 0 m standards internally and 2 0 m standards externally In order to be able to fit guardrails prior to decking using HAKI s advance guardrail tool or with the aid o...

Page 24: ...e scrapped and replaced by new material Around a standard between two lifts or around the lower tube in a ledger beam LB AL fitted between two standards PLEASE NOTE It is not permissible to attach aro...

Page 25: ...25 Notes...

Page 26: ...26 Notes...

Page 27: ...27 Notes...

Page 28: ...tance to wall or similar as short as possible 3 Scaffold aligned correctly horizontally and vertically 4 Components correctly fi tted and locked 5 Bracing correctly fi tted 6 Anchoring with right numb...