20
Permissible loads on beams
Permissible loads on beams installed in HAKI standards.
1 kN = 100 kp
Brackets
Each level at which a bracket is fitted must be
provided with a wall tie.
Load classes for brackets apply provided that the
brackets are fitted in a bay of length max.
3050 mm and in connection with decking of
weight 16.5 kg/m
2
.
In the specified weight classes, no consideration
has been paid to the bearing capacity of the
decking. The permissible load class can never be
greater than the load class for the decking.
Bracket
Load class
SK 230 AL
SK 460 AL
SK 564 AL
SK 770 AL
SK 1250 AL
6
4
3
3
3
Beam type
Permissible
load q
[kN/m]
Permissible
distributed
load Q [kN]
Permissible
centrepoint
loads P [kN]
Permissible
point loads
P
3
[kN]
Permissible
point loads
P
4
[kN
LB 350 AL
LB 770 AL
LB 1050 AL
LB 1250 AL
LB 1655 AL
LB 1964 AL
LB 2500 AL
LB 3050 AL
141.8
59.1
42.5
30.1
16.8
11.8
7.2
4.8
42.5
42.5
42.5
36.1
27.0
22.6
17.6
14.4
42.5
30.1
21.7
18.1
13.5
11.3
8.8
7.2
21.3
21.3
16.3
13.6
10.1
8.5
6.6
5.4
21.3
21.3
21.3
18.1
13.5
11.3
8.8
7.2
ERB 700 AL
ERB 770 AL
ERB 1050 AL
ERB 1250 AL
ERB 1655 AL
ERB 1964 AL
ERB 2500 AL
ERB 3050 AL
26.2
23.6
17.0
11.8
5.6
3.8
2.4
1.6
17.0
17.0
17.0
14.2
9.0
7.3
6.0
4.7
8.5
8.5
8.5
7.1
4.5
3.7
3.0
2.4
6.4
6.4
6.4
5.3
3.4
2.8
2.3
1.8
8.5
8.5
8.5
7.1
4.5
3.7
3.0
2.4
LOADING CONDITIONS
Summary of Contents for UNIVERSAL ALUMINIUM S4
Page 1: ...ALUMINIUM USER S MANUAL HAKI UNIVERSAL S4 HAKI AB 2019...
Page 25: ...25 Notes...