HYDROK
Use and limits of use
54
Order h49 7144.907-333
Size of the
clamping de-
vice
Clamping / release time
𝒕
[
𝒔
]
1
Clamping de-
vice
2
Clamping de-
vice
4
Clamping de-
vice
52
0.656
1.313
2.625
65
0.844
1.688
3.375
100
2.438
4.875
9.750
100*
2.269
4.538
9.075
*
Aluminum variant
Table 18: Clamping/release times on a
2
𝑙
𝑚𝑖𝑛
- hydraulic assembly
Size of the
clamping de-
vice
Clamping / release time
𝒕
[
𝒔
]
1
Clamping de-
vice
2
Clamping de-
vice
4
Clamping de-
vice
52
0.328
0.656
1.313
65
0.422
0.844
1.688
100
1.219
2.438
4.875
100*
1.134
2.269
4.538
*
Aluminum variant
Table 19: Clamping / release times on a
4
𝑙
𝑚𝑖𝑛
- hydraulic assembly
Size of the
clamping de-
vice
Clamping / release time
𝒕
[
𝒔
]
1
Clamping de-
vice
2
Clamping de-
vice
4
Clamping de-
vice
52
0.164
0.328
0.656
65
0.211
0.422
0.844
100
0.609
1.219
2.438
100*
0.567
1.134
2.269
*
Aluminum variant
Table 20: Clamping / release times on a
8
𝑙
𝑚𝑖𝑛
- hydraulic assembly
Calculation of the clamping and release time:
𝑡 =
𝑉
𝜗
=
0.028𝑙
4
𝑙
60𝑠
= 0.422𝑠