Serial
No.
Temperature scope
Frequency limitation
1
Wh_c<-12
Max_hz8 120 HZ
2
Wh_c<-8
Max_hz7 120HZ
3
Wh_c<-2
Max_h z4 120 HZ
4
Wh_c<5
Max_hz5 120HZ
5
Wh_c<12
Max_hz1 100HZ
6
Wh_c<18
Max_hz2 56 HZ
7
Wh_c> 18
Max_hz6 44 HZ
Remarks: the above are the maximum frequency limitations of the complete appliance which are
affected by the environment, and they have nothing to do with the ability of the indoor unit.
Refrigeration/dehumidification mode::
Serial No.
Temperature scope
Frequency limitation
1
Wh_c<16
Max_hz1 26 HZ
2
Wh_c<24
Max_hz2 40 HZ
3
Wh_c<32
Max_hz3 58 HZ
4
Wh_c<44
Max_hz4 80 HZ
5
Wh_c>44
Max_hz5 40 HZ
Remarks: the above are not only the maximum frequency limitations of the complete appliance
which are affected by the environment, but also the maximum ability limitation of the system.
When the starting ability is not the maximum, its maximum frequency limitation is calculated by
the following equations:
The frequency limitation which is affected by the temperature and under the condition of actual
ability
the actural running system ability*the maximum frequency which is limited by the
temperature and under the condition of maximum ability/the maximum designing ability of the
system
T=
Ti*Pi / Pi ( Ti=|Tst_i-Tnh_i the indoor environment temperature| ;Pi i the
ability of the indoor unit)
Refrigeration/dehumidification:
Heating mode
K= Ki/the number of running machines
T
<1
1
2
3
>=4
The percentage of
the rated frequency P
50%
70%
100%
120%
140%
T
<1
1
2
3
>=4
The percentage of the
rated frequency P
50%
70%
100%
130%
180%
The indoor set
airflow speed
Breeze Low
Medium High
Strong Quiet Healthy
airflow
The percentage
of
the
rated
frequency Ki
70
80% 90%
100% 120%
70%
70%
Functions and control
Domestic air conditioner
17
Summary of Contents for Z/N-Series
Page 11: ... Pinping diagrams Domestic air conditioner 4ˊPinping diagrams 9 ...
Page 12: ... Operation range Domestic air conditioner 5ˊOperation range 10 ...
Page 15: ...CN9 CN10 CN36 CN3 CN23 CN24 CN25 CN28 PCB 1 Wiring diagram Domestic air conditioner 13 ...
Page 17: ...Wiring diagram Domestic air conditioner 15 ...
Page 36: ...WARNING CAUTION Installations Domestic air conditioner 34 ...
Page 37: ...Installations Domestic air conditioner 35 ...
Page 38: ...Installations Domestic air conditioner 36 ...
Page 39: ...Installations Domestic air conditioner 37 ...
Page 40: ...Installations Domestic air conditioner 38 ...
Page 41: ...Installations Domestic air conditioner 39 ...
Page 42: ...Installations Domestic air conditioner 40 ...
Page 45: ...Pressurize for over 3 minutes at 4 2MPa After above Installations Domestic air conditioner 43 ...