Super Match
Operation
3.Time setting of timing switch
A. After the timing items for week have been set, each group of set timing information displays 5 seconds
cyclically; when it is displayed in the timing information group, press the "Downward"key to initiate the time
setting of the timing switch of the current group;
B. The cursor is flickering where it stays; when the right function key, as an "Enter"key, is pressed, the cursor
becomes static, which indicates that it is in the adjustment state; press the upward-downward key to adjust the
time and temperature. After adjustment of time and temperature, move the cursor leftward and rightward to
confirm the time and temperature.
C. For adjustment of time, keep the "Upward"key or "Downward"pressed down for 5s, the clock change will
accelerate, with acceleration frequency of 10times/s.
D. During flicker of the cursor, move upward, downward, leftward or rightward to select the circle below; use
the right function key, as an "Enter"key, to confirm or cancel the setting;
represents setting valid and
represents setting invalid.
E. If is present in a timing item containing week, this means the corresponding timing information is valid.
4. Deletion of timing information
If, in a "Weekly timer"interface, the cursor is at"
"press the leftward-rightward key to select
; then press
"Enter"key to pop out the window as shown in Figure 4. Then press the left key or right key to delete or retain the
timing information.
5. Timing switch on/off conflict prompt:
if the timing has been set in such a way that timing on/off setting
conflicts occur at the same time on the same day, those shown in Figure 5 will pop out.
Note: In the time setting state of week timing(cursor still), if no order input for 1 minute, screen saver will be
activated and it will automatically return to main interface; In which state, non-conflicting orders are effective and
otherwise no interface popping out; Latter input conflicting orders are ineffective with NON-SET state displaying
Figure 4
151