7-8. Installation Instructions
THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE
PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE
REQUIREMENTS OF THE CSA B149.1, INSTALLATION CODE.
THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORITY
HAVING JURISDICTION. THE INFORMATION IN THESE INSTRUCTIONS MUST BE FOLLOWED TO MINIMIZE
THE RISK OF FIRE OR EXPLOSION OR TO PREVENT PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
THE QUALIFIED SERVICE AGENCY IS RESPONSIBLE FOR THE PROPER INSTALLATION OF THIS KIT. THE
INSTALLATION IS NOT PROPER AND COMPLETE UNTIL THE OPERATION OF THE CONVERTED APPLIANCE IS
CHECKED AS SPECIFIED IN THE MANUFACTURER'S INSTRUCTIONS SUPPLIED WITH THIS KIT
WARNING
Natural Gas to LP Gas Conversion Kit No.
Important Note:
Installation of this kit converts the dryer from use with Natural Gas to use with LP Gas for
altitudes up to 4,500 feet above sea level. For installations at an altitude greater than 4,500 feet above sea
level, contact a qualified service agency for derating instructions.
Parts List
1 0030101224 Regulator Blocking Plug and
Main Burner Orifice No. 55
1 00305027
06
LP Gas Conversion Plate Sticker
1 00305027
05 LP Gas Conversion Service Sticker (English)
1 00305027
05A LP Gas Conversion Service Sticker (French)
1 00305027
04 LP Gas Valve Sticker (English)
1 00305027
04A LP Gas Valve Sticker (French)
1 00305027
15B
Instructions
Gas input - 20,000 BTU/HR
Before converting the dryer to LP Gas, verify
that the incoming gas supply line is equipped
with a pressure regulator (located ahead of the
dryer) that will maintain the gas supply to the
dryer at
12.5 ± 1.5'' W.C. (31.8 ± 3.8cm W.C.)
Use a U'' tube manometer (or similar pressure
gauge) to check the pressure.
Installation Instructions
1. Disconnect the electrical power
to the dryer.
2. Shut off the gas supply to the dryer.
3. Remove the louvered vent panel
on the rear of the dryer. Disengage the
drum belt by rotating the idler pulley
down and away from the motor. Slide
the belt off of the pulleys. (Figure 1)
Regulator Blocking Plug
Main Burner Orifice
003080 8
79 9
Figure 1
Idler Pulley
Motor Pulley
Drum Belt
.
''
Dryer Models GDG750AW & RDG350AW & Other Natural Gas Dryers