background image

SERVICE MANUL

Model No.HLTD500AGW

Issue

Rev.

- 21 -

Figure 2



1.0 in (25mm)
to edge of 
bracket

Line indicating the distance
from the wall to the back of 
the dryer

Correct Bracket Orientation

11.0 in (280mm)
to edge of bracket

TOP VIEW

11.0 in (280mm)
to edge of bracket

1.0 in (25mm)
to edge of 
bracket

Summary of Contents for HLTD500AGW

Page 1: ...ce a product Products powered by electricity should be serviced or repaired only by experienced professional technicians Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death Model No HLTD500AGW Top Load Electric Dryer Order No TL1501S002V1 1 WARNING 2008 Haier Dryer Machine All rights reserved Unautho...

Page 2: ...Guidance ______________________________________________ Chapter 5 Drying Mathods __________________________________________________ 5 1 Preparations before drying _____________________________________________ 5 2 Load clothes into dryer ________________________________________________ 5 3 Selecting Drying program ______________________________________________ Chapter 6 Appearance brief introductio...

Page 3: ..._____________________________________________ SERVICE MANUL Model No HLTD500AGW Issue Rev 2 25 25 26 27 28 28 30 30 30 31 32 32 33 9 2 4 Use the AUTOMATIC CYCLES program the dryer is drying but the clothes can t intensive drying end the program_________________ ________________ 9 2 3 Press the Start Pause button once the dryer have no action the cycle signal will beep twice________________________...

Page 4: ...were removed in order to service are put in the original positions or whether there are the portions which are deteriorated around the service places serviced or not And be sure safety of that 1 2 Caution and Warning symbols You will see them in Matters needing attention Any instructions in this service manual with this Warning sign must be followed strictly 1 3 Function indication symbols You wil...

Page 5: ...tumble periodically for an hour after the dry cycle is completed and the wrinkle time also can be adjusted To stop simply open the door and remove the clothes The dryer is equipped with an audible signal that alert you every time the dryer load is finished drying Drying machines HLTD500AGW Product identification Description of appliance Drying machine Type of appliance FS standing BI built in FS S...

Page 6: ...ube Packing dimensions loadability 0 7 1 1 8 3 8 6 6 7 m m m m H x D x W s n o i s n e m i d g n i k c a P Gross weight kg 67 6 40 Container load pcs 84 Logistic recicling information RS Packing weight lb 15 Packing materials Recycling symbols EPS t h g i e w n o t r a C gr Shrink package t h g i e w n e r y t s i l o P gr t h g i e w l i o f e n e l y t e y l o P gr t h g i e w s l a i r e t a m ...

Page 7: ...atest editions for HOME USE ONLY This dryer is not recommended for commercial application such as restaurants beauty salons etc For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or loss of life Combustible materials gasoline and other flammable vapors and liquids must not be stored near the dryer ...

Page 8: ...r with controls 8 Do not repair or replace any part of the appliance or attempt any servicing unless specifically recommended in the user repair instructions that you understand and have skills to carry out 9 Do not use fabric softeners or products to eliminate static unless recommended by the manufacturers of the fabric softener or product 10 Do not use heat to dry articles or products to elimina...

Page 9: ...e plastic flexible duct to exhaust the dryer Excessive lint can build up inside exhaust system and create a fire hazard and restrict air flow Restricted air flow will increase drying time If your present system is made up of plastic duct or metal foil duct replace it with a rigid or flexible metal duct Ensure present duct is free of any lint prior to installing dryer duct 2 The dryer must not be e...

Page 10: ...e duct 7 Do not allow combustible material clothing draperies curtains paper etc to come in contact with exhaust system Explosion hazard Do not install the dryer where gasoline or other flammables are kept or stored If the dryer is installed in a garage it must be a minimum of 18 inches 45 7cm above the floor Failure to do so can result in death explosion fire or burns ...

Page 11: ...ff when a dry cycle is started B C CYCLE SELECTION KNOB Use this button to turn power to the dryer on and to turn the power off NOTE If the dryer is powered on and is not started it will automatically turn off after about 5 minutes NOTE This button works with automatic cycles only There are 6 Automatic Cycles Sanitize Use this cycle to help sanitize items such as towels bedding and children s clot...

Page 12: ...d of cycle signal Eco Dry Perm Press Delicate Use this cycle to save energy The program is similar to Normal but uses a slightly lower temperature and dries to a slightly lower dry level Use this cycle for low temperature heat and wrinkle free fabrics Use this cycle for extra low heat to gently dry delicate items Timed Dry Quick Dry Touch up Rack Dry There are 4 Timed Dry Cycles to choose from Use...

Page 13: ...eavy Duty Heavyweight items such as towels and jeans 60 High Normal Normal Wrinkle Saver Damp Signal More More Less Normal Cottons linens and mixed garments 52 Medium WrinkleSaver DampSignal Less Eco Dry Cottons linens and mixed garments 40 Medium Normal Wrinkle Saver Damp Signal More Less Perm Press Cotton poly blends wrinkle free shirts and pants 35 Low Normal Wrinkle Saver Damp Signal More Less...

Page 14: ...entanglement and ensure easy removal Make sure the power socket is reliably grounded The grounding terminal should not be connected to gas or tap water pipelines Make sure exhaust duct has been properly connected Make sure lint filter is clean and properly installed If lint filter is not in place tumbling items could enter the exhaust system and cause damage to the dryer Note Applies to Auto Dry c...

Page 15: ...hapter 6 Appearance brief introduction 6 1 Name of parts 6 2 Net dimension height 1080mm width 686mm depth 777mm SERVICE MANUL Model No HLTD500AGW Issue Rev 14 Power line Gas inlet Gas valve bracket Knob ...

Page 16: ...ystem is acceptable Certain extenuating circumstances could affect the performance of the dryer 1 Only rigid metal duct work should be used 2 Venting vertically through a roof may expose the exhaust system to down drafts causing an increase in vent restriction 3 Running the exhaust system through an uninsulated area may cause condensation and faster accumulation of lint 4 Compression of crimping o...

Page 17: ...ft wall Maximum the dryer and the be used between Circuit Individual 15 Amp branch circuit fused with 15 Amp maximum time delay fuse or circuit breakers Power Supply 3 or 4 wire 120 240 Volt 1 Phase 60Hz AC Power Supply Cord The dryer is equipped with a 120 Volt 3 wire power supply cord There are adjustable feet under the bottom of the dryer Before use the dryer should be adjusted as shown in the ...

Page 18: ...allation must conform with the National Fuel Gas Code ANSI Z223 1 latest edition or in Canada the current CAN CGA B149 1 2 The gas supply line should be 1 2 inch 1 27cm pipe 3 If codes allow flexible metal tubing may be used to connect your dryer to the gas supply line The tubing MUST be constructed of stainless steel or plastic coated brass 4 The gas supply line MUST have an individual manual shu...

Page 19: ...N 0030807988 Manufactured Home Installation Kit Follow the instructions supplied with the kit 5 Refer to previous se ctions for other important venting requirements 6 Installation must confo rm to current Manufactured Home Construction Safety Standard which is a Federal Regulation Title 24 CFR Part 32 80 or when such standard is not applicable with American National Standard for Mobile Homes In Ca...

Page 20: ... Standard which is a Federal Regulation Title 24 CFR Part 32 80 or when such standard is not applicable with American National Standard for Mobile Homes In Canada the CSA Z240 is applicable Dryer MUST be exhausted to the outdoors Refer to the User Manual for dryer exhaust requirements Drer MUST be permanently secured to the floor at the time of installation ...

Page 21: ...o the User Manual for complete exhaust requirements 4 Measure the distance from the back of the dryer to the wall as shown in Figure 1 Measure and mark the centerline of the dryer as well Note that the exhaust duct connection to the dryer is located on the dryer centerline 5 Disconnect the exhaust duct and move the dryer away from the wall allowing adequate room to work behind the dryer Figure 1 1...

Page 22: ... 21 Figure 2 1 0 in 25mm to edge of bracket Line indicating the distance from the wall to the back of the dryer Correct Bracket Orientation 11 0 in 280mm to edge of bracket TOP VIEW 11 0 in 280mm to edge of bracket 1 0 in 25mm to edge of bracket ...

Page 23: ...above sea level For installations at an altitude greater than 4 500 feet above sea level contact a qualified service agency for derating instructions Parts List 1 0030101224 Regulator Blocking Plug and Main Burner Orifice No 55 1 0030502706 LP Gas Conversion Plate Sticker 1 0030502705 LP Gas Conversion Service Sticker English 1 0030502705A LP Gas Conversion Service Sticker French 1 0030502704 LP G...

Page 24: ...emove the vent screw from the top of the gas valve Install the new regulator blocking plug finger tight then tighten it no more than 1 8 turn to seal it Figure 5 12 Apply No 0030502704 LP Gas Valve Converted Sticker over the existing valve label Figure 5 In Canada apply No 0030502704A French 13 Sign and date one of the No 0030502705 LP Gas Service Stickers and apply it adjacent to the exiting data...

Page 25: ...fitting and replace pressure tap plug 23 Turn on gas supply and check for leaks using a soapy solution Caution Do not use an open flame to check for gas leaks 24 Shut off gas supply to the dryer 25 Verify that the dryer conversion has been completed Recheck the following Installed Main Burner Orifice 55 Step 11 Installed Regulator Blocking Plug Step 12 Verified gas inlet pressure is 12 5 1 5 W C I...

Page 26: ... does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happens turn the dryer to OFF and wait 5 minutes before making another attempt to light NOTE Follow instructons supplied with kit CAUTION 2 Connect a 1 2 inch 1 27cm I D semi rigid or approved pipe from gas supply line to the 3 8 inch 0 96cm pipe located on the back of the dry...

Page 27: ...o adapter and gas inlet B Attach the flexible metal gas line connector to the adapter C Make sure flexible gas line seal is secure Use two wrenches for the best possible connection D To check gas inlet pressure attach 1 8 NPT plugged tapping to dryer gas line shut off valve Then connect flare union adapter to plugged tapping Affix Teflon tape to the threads of the adapter and plugged tapping to en...

Page 28: ...3 0 4 2A 120 V 15 A resistive 71ºC functioning temperature 10 k T80 5 75A 120 AC 60Hz 110V 120V 10W Lamp T 0ºC R 32 533k T 15ºC R 15 701k T 30ºC R 8 059k T 45ºC R 4 372k T 60ºC R 2 491k T 75ºC R 1 482k 25M01A S58TVHCM 7135 D2 60T21 36FXE14 E17 Belt switch DC 037 120 60Hz 0 12A 10RS AK 47 1 15 A 125V 60Hz 96 39 11 4 121 128 118 121 120 103 57 46 N G POWER PCB White DOOR SWITCH Brown LAMP L1 DISPLAY...

Page 29: ...heck if the wire connecting of the NTC1 and PCB is disconnection Cut off the power Check if the wire unit is good Check if the PCB is good Well Replace the Back up thermostat and make sure wire is connected properly Broken Replace the wire unit N 9 1 2 The Digital Tube display E6 the Clean Lint indicator light is twinkling Error message The lint filter need clean or the exhaust system is not good ...

Page 30: ...ting the dryer to the gas supply and the gas shut off valve is open the gas supply accord with the dryer s requirements Connecting the dryer to the gas supply open the shut off valve insure the gas supply is well Replace the ignitor insure the exhaust system is well Check if the wire connecting the radiant sensor the hi limit thermostat the cycling thermostat and the wire unit Check if the radiant...

Page 31: ...t but the dryer no action Troubleshooting Check if the wire connecting of the motor is ok Connect the wire properly N Y Cut off the power Check if the belt is break off or the connecting of the motor belt switch is loose Replace the belt or connect the wire properly Check if the tensive arm unit is installed well Reinstall the tensive wheel unit and try rotating the tub manually Check if the belt ...

Page 32: ...al broken that replace the drum seal Check if the drum seal is airproof N Y 9 2 3 Press the Start Pause button once the dryer have no action the cycle signal will beep twice Error message Door is not closed Troubleshooting Confirm that the door is closed Close the door Connect the wire properly Replace the door switch and make sure wire is connected properly Cut off the power Check if the wire con...

Page 33: ...if some screw become flexible Replace the worm shell Reinstall them and let the drum can t touch anything Y N N N Y Y Y Check if the frictional slice and the wool felt is well N Replace the broken part Y 9 2 5 Use the AUTOMATIC CYCLES program the clothes is very dry but the dryer is drying at all times N Check if the terminal of the humidity sensor is ok check if between two metallic humiditty sen...

Page 34: ... remove dust and particles trapped in the filter Lint built up in screen will restrict airflows which causes longer drying times After cleaning slide the filter back in place Do not use your dryer without the lint filter Do not use any type of spray cleaner when cleaning the interior r If dryer drum becomes stained clean the drum with damp cloth Remove any residue before drying next load r Do not ...

Page 35: ...Sincere Forever Haier Industrial Park No 1 Haier Road 266101 Qingdao China http www haier com Printed in China Group ...

Reviews: