electronic expansion valve
AS06
AS06
7.1.5
Combination example:
8 by 1:
NOTE:
1.When AU48 unit is connected with 8 indoor units, pay attention that the total capacity of indoor
units must not exceed 130% of outdoor cooling capacity.
2.Wall-mounted type can not be connected with 8 units by the outdoor unit. But you can refer to
the above combination example.
3.when outdoor unit connects with
8
colorful screen
wall-mounted units
,
please
set address by
dialing switch. When you connect old wall type units, you only can connect max 6 sets, and
set
their addresses with address setting controller.
4.when outdoor unit connects with 8 units according to <admissible combination
example>(except for the No.3 example), please set address of the anterior 6 indoor units with
the address-setting remote controller, and then set address of the latter 2 indoor units with
dialing switches.
Or using below method to set unit 7 and 8:
Press button 6 and at the same time in 2
seconds press button 1, then loosen them simultaneously. The LCD will display “7”, which
stands for selecting unit 7. And then press button “set”, you can set unit 7.
By the same method, press button 6 plus button 2, you can set unit 8.
>a__WcU[S^ <[c >a`V[e[a`Wc
-58-
Summary of Contents for H-MRV AF092FCBHA
Page 121: ... _ VbTZR Zb _ UZdZ_ Vb AU242FHBHA PCB top layer printed diagram 121 ...
Page 122: ... _ VbTZR Zb _ UZdZ_ Vb AU242FHBHA PCB bottom layer printed diagram 122 ...
Page 127: ... _ VbTZR Zb _ UZdZ_ Vb AU482FIBHA high voltage PCB printed diagram 127 ...
Page 131: ... _ VbTZR Zb _ UZdZ_ Vb AU482FIBHA low voltage PCB printed diagram 131 ...
Page 152: ... a__WcU S c a V e a Wc AB092 182FCBHA PCB printed diagram 152 ...
Page 156: ... a__WcU S c a V e a Wc AE FCBKA PCB printed diagram 156 ...
Page 199: ...MEMO Commercial Air Conditioner ...