Operation Method
For example: To adjust the time to 11:29
After the startup of this unit, under standard and night power mode, press setting button to enter into clock
adjustment status, the hour digit of the clock will flash, press
∧
or
∨
to adjust the value to 11, press setting
button again, the minute digit of clock will flash, press
∧
or
∨
to adjust the value to 29, press setting button to
confirm the current setting, or the system will automatic confirm six seconds after non-operation and exit setting
mode (as shown in Fig. 10, this unit is under heating/heat preservation status of standard mode).
For example: As shown in Fig. 11, this unit is under standard mode of water storage type, and the status of
heating/ heat preservation of setting temperature of 65
℃
.
5.
Standard Mode Setting
Under water storage mode after the startup of this unit, refer to the method mentioned in the second clause, press
the mode button to enter into standard heating/heat preservation working mode, and at this moment the standard
symbol will be illuminated. This unit will automatically start heating or enter heat preservation mode according to
setting requirement. Meanwhile this unit has an automatic thermostat control function, and it will enter heat
preservation status after the heating reaches the setting temperature. Under heat preservation status, when the
actual water temperature is less than 5
℃
, the setting temperature (at this moment the setting temperature is less
than 55
℃
) or 1
0℃
than the setting temperature (at this moment the setting temperature is greater than or equal to
55
℃
), the unit will automatically reheat to the setting temperature and hold such temperature, and the cycle is like
this.
6.
Medium-temperature Heat Preservation Setting
Under water storage type mode after the startup of this unit, refer to the method mentioned in the second clause,
press mode button to enter the working mode of medium-temperature heat preservation (indicate the selected
medium-temperature/heat preservation symbol), at this moment the water heater will automatically select the most
energy-saving heat preservation temperature [at normal times, such temperature can meet the demands of hot
water with smaller amount, and it is not suitable to take bath. It shall exit the medium-temperature/heat
preservation status during bathing period, and press the mode button to enter into standard heating/heat
preservation mode, or use prompt/storage button to convert the working mode of this unit to prompt heating
(“prompt heating” will be illuminated), and at this moment this unit can heat the water to the setting temperature
within short time] at the range of 35
℃~
40
℃
according to the temperature difference of the water temperature
and ambient temperature. Under medium-temperature/heat preservation mode, when the water temperature is
reduced to 35
℃
, this unit will begin reheating.
For example, as shown in Fig. 12, the system is in medium-temperature/heat preservation mode, at this moment
the actual water temperature is 52
℃
. When the actual water temperature is reduced to 35
℃
, the unit will
automatically reheat to 40
℃
, and meanwhile enter into heat preservation status, and the cycle is like this. In the
mode, the unit will imply the maximum heating temperature is 40
℃
, which can’t be adjusted.
12
Prompt Heating Type
Actual
Heating
Standard
(Fig. 10)
Prompt Heating Type
Heating
Standard
Setting
(Fig. 11)
Water Storage Type
Actual
Heat Preservation