background image

 

Operation Method  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For example, as shown in Fig.14, to set reservation 1 of water use to 10:30. 
Under water storage type mode after the startup of this unit, continuously press the mode button to enter the 
working mode of reservation 1, the reservation symbol and figure will be illuminated simultaneously, press setting 
button to enter the hour setting status of reservation 1, the hour digit of reservation 1 will flash, and press 

 or 

 

to adjust to 10:00. Press setting button to confirm the setting and enter into the minute setting status of reservation 
1. Press 

 or 

 to adjust the value to 10:30. At this moment you can press setting button to confirm the current 

setting, or this unit will conduct automatic confirmation and exit the setting about six seconds after non-operation. 
The time setting process of reservation 2 is similar to that of reservation 1, namely use mode button to adjust the 
working mode of this unit to the working mode of reservation 2, and use setting button to conduct the time setting 
of reservation 2. 
Note: If this unit is under reservation status, and a large amount of hot water is demanded after the heating of 
water has started, it will result failure reach to setting temperature after the water heater reaches the reservation 
time. The unit will automatically delay the heating for half an hour and it will stop after that. If the actual water 
temperature has reached setting temperature before the reservation time, and meanwhile it hasn’t reached 
reservation time after the actual water temperature is reduced, this unit will conduct the calculation of heating time 
again, and determine if it needs to conduct heating again. In like manner, if the voltage of electric network is too 
low, the heating power of water heater will not reach 2000W/1500W, and it will result failure to reach the set 
temperature value after the water heater has reached reservation time, this unit will automatically delay the 
heating for half an hour and it will stop after that. 

 

10.

 

Standby 

When bathing is finished, directly press the ON/OFF button to enter into standby status. 

‹

 

Warming Hints: 

A.

 

Under a specific mode after the startup of this unit, press setting button to set ON/OFF time of each mode, 
and adjust the time through 

 or 

. If it is in prompt heating mode, you can press setting button to adjust 

hour and minute of clock; and under reservation mode, you can press the setting button to set the reservation 
time. The setting button is disabled under medium-temperature/heat preservation and intelligent modes. 

B.

 

This unit has many safety protection devices, such as electricity leakage protection, over-temperature 
protection, and short-circuit and open-circuit protection sensors, and it can realize full-circuit disconnection 
and indicate fault codes. All fault protections are irrecoverable protection, and you must contact the after-sales 
service department. 

C.

 

This electric water heater has a power-failure memory function, there is no need to reset heating power, 
heating temperature, clock, and working mode after a power failure, and it will directly enter the same 
working status of water storage type before the power failure. 

D.

 

In intelligent non-heating status, this unit is under standby status, and you can activate the interface through 
any button on the control panel. 

E.

 

In order to ensure the normal use of this unit, it is suggested that it should be kept away from any source of 
disturbance (e.g. mobile phone). If there is any disturbance, this unit will enter anti-disturbance protection 
status, and it will automatically resume one minute after the source of disturbance has been removed. 

                                                                                          14 

Water Storage Type 

Setting

Heat 

Preserv

ation 

(Fig. 14)

 

Reservation 

Summary of Contents for FCD-HM50

Page 1: ...eater Operation Instruction FCD HM40GI E FCD HM50GI E FCD HM60GI E FCD HM80GI E FCD HM100GI E z Please carefully read this operation instruction prior to the use of this unit z Please store these operation instructions properly for future reference ...

Page 2: ...fety Warning Expert Logo of a Haier Safety Water Heater This marking is the exclusive marking of Safety Warning Expert of the Haier Water Heater Company The interior uses the patent technology which will constantly monitor if the earth wire of your residence is live while ensuring you can bathe safely If you finds that this marking is illuminated it means that your family s earth wire is live if t...

Page 3: ...r to Use Packing List 5 Special Notices 5 Installation Guide Installation Points of Attention 6 Installation Method 6 8 Operation Guide Introduction of Control Panel 9 Operation Sketch Map 9 Operation Method 10 15 Operation Points of Attention 15 Cleaning Maintenance of Unit 15 16 Keys to Difficulties Keys to Difficulties 16 Appearance color or figure of the water heater refers to the actual unit ...

Page 4: ...t Operation The heating water temperature can be set and adjusted between a range of 35 75 with intervals of 5 The outlet temperature can be adjusted randomly at the range of inlet temperature 75 and the operation is simple and flexible This unit adopts a prompt heating design and top heating technology which can meet the demand for hot water instantaneously Prompt heating type and water storage t...

Page 5: ...E 50 220V 50Hz 3000 Prompt 1500 Storage 0 75 75 IPX4 22 666 494 100 409 2 5 16A FCD HM60GI E 60 220V 50Hz 3000 Prompt 2000 Storage 0 75 75 IPX4 25 770 494 100 409 2 5 16A FCD HM80GI E 80 220V 50Hz 3000 Prompt 2000 Storage 0 75 75 IPX4 29 876 530 100 432 2 5 16A FCD HM100GI E 100 220V 50Hz 3000 Prompt 2000 Storage 0 75 75 IPX4 34 1042 530 100 432 2 5 16A Note The allowable tolerance range of the ab...

Page 6: ...ue to water freezing z If the power wire of the electric water heater is damaged it must be replaced with a special wire provided by manufacturer by after sales serviceman No one is allowed to conduct the dismantlement except for professional technical serviceman In addition don t place flammable objects near water heater The water temperature value indicated in the display screen is the water tem...

Page 7: ...can t be drained z If this unit is to be connected with a drain pipe connect the drain pipe with the opening of the sewage pipe to avoid sewage spraying indoors The machine configuration pipe of this unit is an integral part of the shockproof wall product do not dismantle it otherwise our company will not take responsibility for any injury resulting from that Symbols Description Don t operate If i...

Page 8: ...e power socket is in conformity with national standards and was reliably connected to the earthing wire It is strictly prohibited to use the water heater without reliable earthing z This electric water heater is equipped with a safety valve For the safety of operation changing the installation position willfully is not allowed and it is prohibited to block the outlet of the safety valve z When amb...

Page 9: ...responding protection measures such as additional installation of a bracket use of wall screw or installation of backing plate z The installation position of the electric water heater shall be chosen at places where is convenient for operation maintenance and there is a floor drain If the water tank or water tube leaks it should not cause damage to the surroundings or underside facilities The inst...

Page 10: ... wall holes secure the hooks and bolts raise the water heater put the wall mounted bracket on the hooks and bolts install the flat washers back wiring of water heater and nuts onto the bolts in the proper order as shown in Fig 3 and tighten the nut and check if it is secured z In order to facilitate the installation and dismantlement of water heater it is suggested to additionally install G1 2 mov...

Page 11: ...water and there is no leakage at each joint and the power is in conformity with requirement Fig 5 Wall mounted Installation Method The water heater is machine controlled device before delivery and users can adopt the following method to change to a line controlled installation z Firstly push out the bottom cover in a the direction away from transparent decoration accessories to dismantle the botto...

Page 12: ...tton at Water Storage Mode Prompt heating Top heating Instant Heating Water Storage Heating You can chose between Standard Medium temperature Heat Preservation Night Power Reservation Intelligent Standard Hour digital adjustment of clock Press setting button Minute Digital Adjustment of clock Medium temperature Heat Preservation Night Power Press setting button Hour digital adjustment of clock Min...

Page 13: ...tus if the water storage type is illuminated this unit will imply the heating power is 2000W the implied power value of 40 50L unit is 1500W for each press of the mode button the system will cycle between the statuses of standard indicates standard symbols medium temperature heat preservation indicates medium temperature heat preservation symbols night power indicates night power symbol preservati...

Page 14: ... Conversion Method of Prompt Heating Mode Under any water storage type of startup status press the prompt storage button to enter prompt heating mode prompt heating type will be illuminated the time will count down with the limitation of 30 minutes and the display panel will indicate the decrease in the range of 30 00 00 00 If the system detects that the water flow is greater than or equal to 2L m...

Page 15: ...e setting temperature and hold such temperature and the cycle is like this 6 Medium temperature Heat Preservation Setting Under water storage type mode after the startup of this unit refer to the method mentioned in the second clause press mode button to enter the working mode of medium temperature heat preservation indicate the selected medium temperature heat preservation symbol at this moment t...

Page 16: ...ance heating according to the recorded water use time In water storage type mode after the startup of this unit continuously press the mode button to enter intelligent working mode the intelligent symbol will be illuminated the system will enter into heating status with the event of the first heating time after the current time and the maximum heating temperature can be set manually During non hea...

Page 17: ...water heater will not reach 2000W 1500W and it will result failure to reach the set temperature value after the water heater has reached reservation time this unit will automatically delay the heating for half an hour and it will stop after that 10 Standby When bathing is finished directly press the ON OFF button to enter into standby status Warming Hints A Under a specific mode after the startup ...

Page 18: ...If the water heater is to be not used for a long time you can close the valve of the water pipe open handle of the safety valve push the mixing valve of water heater to the maximum hot water level and drain the water inside the interior shell Before the use of second time in order to avoid the occurrence of injury or accident it is suggested to open the valve of the hot water before the connection...

Page 19: ...pen 2 If water temperature is adjusted Conduct correction according to operation method shown in instruction manual 3 The heating time is too short and it hasn t reached setting temperature Outlet is cold water 4 If elements are damaged Please contact the service department if it is not the items shown in 1 2 and 3 1 If the current function mode is correctly set and if the temperature setting is t...

Page 20: ...p Haier Water Heater Co Ltd Qingdao Economic and Technical Development Zone Version 1 Address Haier Industrial Park Qingdao Economic and Technical Development Zone Special SN 0040500 Website http www haier com VC ...

Reviews: