21
HAI Communicating Thermostats and the Programmable Energy Saver Module (PESM) provides energy savings, comfort, and
convenience by setting the HVAC system(s) to the proper temperature based on whether you are home, asleep, away, or vacation.
The temperature can be reported as well as controlled over any telephone. A freeze alarm feature will cause a dial out if the
temperature falls below a preset level.
The HAI Communicating Thermostats are digital heating and cooling thermostats that can be controlled be the user and by remote
control. There are models for conventional single stage (gas or electric), heat pumps, and multi stage heating and cooling
systems. All models offer programmability, stand-alone operation, and robust communication to the OmniLT system.
HAI RC-Series Thermostats
The following control actions are allowed for HAI Communicating Thermostats:
•
Set heating setpoints
•
Set cooling setpoints
•
Set system mode (Off / Heat / Cool / Auto)
•
Set fan (On / Auto)
•
Turn hold On and Off
NOTE:
Not all actions are applicable to every type of thermostat.
To enter the temperature menu, from the top-level display or from the main menu, press the 5 (TEMP) key on the console keypad.
You will be prompted with the first named temperature zone (i.e. Upstairs). The temperature zone can be specified by entering
the temperature zone number followed by the ' # ' key, or by pressing the arrow keys to scroll through the list of temperature
zones. Press the ' # ' key when the desired temperature zone is shown.
Press the ' 0 ' key to select all HAI Thermostats. This is a simple way to broadcast the new Heat or Cool setting or change the
system mode, fan mode, or hold mode of all HAI thermostats in your system. Temperature zones 1 & 2 are for HAI termostats.
TEMPERATURE:
ENTER TEMP ZONE 0=ALL
↓
After the ' # ' key is pressed, a menu appropriate for the type of temperature zone is shown. For Celsius temperatures, press the ' #
' key prior to entering the temperature to make the number negative. The Celsius temperature may also be specified in 0.5 degree
steps, if three numeric digits are entered. The third digit adds a .5 to the first two digits, if it is anything other than zero. Enter a
leading zero, if necessary.
For HAI heat/cool thermostats:
Upstairs
1=MODE 2=HEAT 3=COOL
↓
Upstairs
4=FAN 5=HOLD #=STAT
↑
To change the system mode on a thermostat, press 1 (MODE). A menu presenting options appropriate for that type of thermostat
is then displayed.
For heat/cool thermostats with auto changeover:
Upstairs MODE
0=OFF 1=HEAT 2=COOL
↓
Upstairs
MODE
3=AUTO
↑
To change a temperature setting, press 2 (HEAT), 3 (COOL), or 2 (TEMP) as appropriate:
Summary of Contents for OMNI LT
Page 1: ...Owner s Manual Document Number 21R00 1 Rev 2 4 May 2003...
Page 68: ......
Page 69: ......