17
The rate specifies the time it takes the switch to go from full off to full on, or from full on to full off. Thus a level change from
full off to 50% on will take half the time specified.
Before any digits are entered, the ' # ' key may be used to switch between specifying the rate in minutes, seconds, and hours.
After you choose between minutes, seconds, and hours, enter the rate (2-99 seconds, 1-99 minutes, or 1-10 hours).
Next, enter a number (0-100) to indicate the final lighting level (intensity) desired.
LIGHTING LEVEL:
0-100%:
The keypad will beep and the lighting level will be adjusted. The keypad display top line will read:
DEN LIGHTS 40% AT 1H
Scene Command (Compose)
If Compose lighting switches are part of your installation, the Scene (SCN) command is used to set a group of lights to predefined
lighting levels. There is an Off command, an On command, and 12 lighting scenes for each group of Compose lighting switches.
SCENE:
0=OFF 1=ON 2-13=A-L
Enter 0, followed by the ' # ' key, to turn the lights that are part of the selected group off. Enter 1, followed by the ' # ' key, to set
the lights that are part of the selected group to predefined lighting levels.
To set the lights in the selected group to a predefined scene, enter the Scene number 2-13 (which corresponds to Scene A-L,
respectively), followed by the ' # ' key. All lights that are part of the selected group are set to the predefined lighting levels for the
selected Scene.
Timed Commands
The timed commands allow a units to be turned on or off for a specified period of time. The unit may be turned On for 1-99
(minutes or seconds), or 1-18 hours, then Off; or turned Off for 1-99 (minutes or seconds) or 1-18 hours, then On.
X-10 units (1-16) may also be dimmed or brightened for a specified period of time. The unit may be dimmed (1-9) steps for 1-99
(minutes or seconds), or 1-18 hours, then brightened back to its previous level; or brightened (1-9) steps for 1-99 (minutes or
seconds), or 1-18 hours, then dimmed back to its previous level.
To enter a timed command, you must first enter the unit that you want to control. From the control menu, enter the unit number
(or scroll to it using the arrow keys), then press the ' # ' key.
To enter a time, press the 9 (TIM) key. Before any digits are entered, the ' # ' key may be used to switch between minutes,
seconds, and hours. After you choose, enter a time (1-99 for seconds & minutes, and 1-18 for hours). Once the time is entered,
the control menu is redisplayed with the specified times shown. For example:
Porch Lights For 2H
0=OFF 1=ON 2=DIM 3=BRT
↓
Status of a Unit
To see the status of an X-10 or ALC unit, from the control menu, press the ' # ' key. The last command along with any time
(hh:mm:ss) remaining on a timed command will be displayed.
Porch Light 1:22:10
LAST
COMMANDED
ON
At this point, one of the menu choices may be entered or the ' * ' or ' # ' key may be pressed to redisplay the menu.