9
OMNILT SETUP
A.
At a console, select "Installer Setup" (press 9, installer code, then #). Press 2 for
“Zones”, and then press 1 # (“Wireless Receiver?” Yes = 1).
B.
When connected to OmniLT, Zones 9-24 are the wireless receiver zones.
C.
When connected to OmniLT, the receiver address on the 45A00-1
must
be set to
"A1" and the number of addresses must be set to "n1".
D.
OmniLT can handle up to 4 transmitters per zone.
The chart below shows the relationship of each wireless transmitter on the 45A00-1
Wireless Receiver to each zone on the OmniLT.
Zones on OmniLT
Transmitter Numbers on Wireless Receiver
Zone 09
1
17
33
49
Zone 10
2
18
34
50
Zone 11
3
19
35
51
Zone 12
4
20
36
52
Zone 13
5
21
37
53
Zone 14
6
22
38
54
Zone 15
7
23
39
55
Zone 16
8
24
40
56
Zone 17
9
25
41
57
Zone
18
10 26 42 58
Zone
19
11 27 43 59
Zone
20
12 28 44 60
Zone
21
13 29 45 61
Zone
22
14 30 46 62
Zone
23
15 31 47 63
Zone
24
16 32 48 64
CONNECTING TO OMNI II, LUMINA, OMNIPRO II, OR LUMINA PRO
Connect the receiver to the Omni II, Lumina, OmniPro II, or Lumina Pro controller
using 4-conductor, 22-gauge or larger wire as follows: