7.00
Push the DISPLAY button to step to the next parameter. The display will show:
Comp. Hard. 00025
This parameter is the calculated compensated hardness using the hardness, iron and manganese settings.
The formula is (4 x each ppm iron) + (4 x each ppm manganese) + hardness = compensated hardness.
This is not a parameter that can be set. The display should now read:
Comp. Hard. 00025
8.00
Push the DISPLAY button to step to the next parameter. The display will show:
Capty. Gr. 24480
This parameter is used to set the softening capacity of the appliance. (For optional cycle settings, see page 36.)
8.00a
Push the SELECT and CHANGE buttons until the desired capacity number is displayed.
In this example, set to:
Capac. Gr. 24480
9.00
Push the DISPLAY button to step to the next parameter. The display will show:
72-96hr Regen Yes
This parameter, if set to “Yes”, is used to force the appliance to regenerate every 96 hours if regularly
scheduled regenerations based on water usage do not occur in 96 hours or less intervals. This should
always be “yes” if iron is present in the water.
9.00a
Push the CHANGE button to toggle parameter value from “No” to “Yes”. In this example, set to:
96hr Regen No
10.00
Push the DISPLAY button to step to the next parameter. The display will show:
Backwash 1 03.0
(See page 36.) The “03.0” is the time, in minutes to the nearest tenth, for which the first
backwash cycle can be set.
10.00a
Push the SELECT and CHANGE buttons until the desired backwash time is displayed.
In this example, set to:
Backwash 1 03.0
11.00 Push the DISPLAY button to step to the next parameter. The display will show:
Brine/Rinse 30.0
The “30.0” is the time, in minutes to the nearest tenth, for which the first brine and slow rinse cycles
can be set.
11.00a
Push the SELECT and CHANGE buttons until the desired combined brine and slow rinse cycle time is
displayed. In this example, set to:
Brine/Rinse 30.0
12.00
Push the DISPLAY button to step to the next parameter. The display will show:
Backwash 2 01.0
The “01.0” is the time, in minutes to the nearest tenth, for which the second backwash can be set.
12.00a
Push the SELECT and CHANGE buttons until the desired backwash time is displayed.
In this example, set to:
Backwash 2 01.0
NOTES: ______________________________________________________________________________________
Series 96 Owner’s Manual
11