e
e
45
44
Power supply to the cooker is switched off and switched on again
immediately.
Cause: Power control unit is connected incorrectly.
Check that the connection of the cooker supply cable and cooker connec-
tion cable have the right terminal assignment (
IN/OUT
).
Water leakage alarm triggers.
Cause: The leakage sensor is not sufficiently dried or is dirty.
Dry or clean water leakage sensor.
Sensor unit does not react when button is pressed.
Cause 1: Battery charge too low.
Replace batteries.
Cause 2: Batteries are not inserted correctly.
Check that the batteries are in the correct position according to the marking
on the bottom of the battery compartment and correct the position if neces-
sary.
The fault signals that possibly occurred and their problem description are listed
in table 6.
Status LED (5) flashes blue
Problem description
●
Problem with the radio connection
●●
Problem with the power control unit
●●●
Power control unit is overheated
Status LED (5) flashes yellow
Problem description
●
Problem with the sensors
●●
Problem with the sensor unit
●●●
Wrong mounting position of the sensor unit
Table 6: Fault signal
6.3 Accessories
Water leakage sensor
WXH202
KNX radio binary input 2gang flush-mounted
TRB302A
KNX radio binary input 2gang flush-mounted 230 V
TRB302B
„
“