Carry out a user reset
Keep
RESET
button (10) pressed for more than 20 seconds, until the RGB LED display (1)
is slowly flashing yellow.
Release
RESET
button (10) briefly and press once again to confirm the selection of the
reset mode.
Rapid yellow flashing of the RCB LED display (1) confirms the successful reset.
1 x
> 20 s
Figure 32: User reset
Carry out rest to factory settings
The device is disconnected from the mains voltage.
Keep
RESET
button (10) pressed and switch on the smartbox by plugging into the (13) pow-
er supply.
The RGB LED display (1) first flashes red approx. 5 times slowly, then flashes red rapidly.
Release the
RESET
button (10) and wait a few minutes until the RGB LED display (1) no
longer flashes.
The reset has been carried out successfully.
Figure 33: Reset to factory setting
RGB LED display
The smartbox has a display (1) for signalling errors that occur or for displaying the process of
operations (see
Table 6
).
signal
Cause
Flashing red
Critical warning, such as fire or burglary
Permanent red light Hardware or software error
Flashing yellow
Technical warning, such as low-battery status of a
device in the installation
Flashing blue
Update, a software update is being installed
Table 6:
RGB LED display (1)