20
BRUSH REPLACEMENT
Brush life will vary depending on the load placed on the
motor. The brushes should be inspected every 10-15
hours of use. To inspect
1. Remove the Brush Holders, one of which is shown
at (A). The other is located in the same position on
the rear of the motor assembly. The Brush Holder
can be removed using a flat blade screwdriver.
SEE FIG 18.
Fig. 18
A
2. Once the brush has been removed, inspect the
carbon (B), the spring (C), and the wire (D).
SEE FIG 19.
Fig. 19
D
C
B
3. If the carbon of either brush is worn down to 3/16”
or less, both brushes should be replaced. Also if
the spring or wire are burned or damaged in any
way, both brushes should be replaced.
BLADE REPLACEMENT
For information on replacing blades refer to the section
labeled ADJUSTING / REPLACING KNIVES in the
ADJUSTMENT section of this manual.
ORGANIZING POWER CORD
Power cord can be organized by circulate on the top two
stock rollers. Clip the plug to the cord.
SEE FIG. 20
Fig. 20
www.machineryhouse.com.au
www.machineryhouse.co.nz
Page 21
Instructions Manual for T-13A (W813)
1