background image

 

 

 

 

5.52.185.01.01.02 

 

 

15 

 

Commissioning 

 

8.1 

General 

Should the unit be used in Germany:  

Please observe the validated, national accident prevention regulations. 

For other countries:  

Inspections as above. Please observe the national rules and regulations and the instructions in this manual! 

 

 

 

NOTICE!

 

Hoists up to 1000 kg capacity and without motor-driven trolleys of hoisting unit must be tested by a “qualified 
person” before putting into operation for the first time. 

Hoists of 1000 kg capacity and up or with more than one motor-driven hoist movement; i.e. lifting and trolley 
movement, must be tested by a “licensed qualified person” before putting in operation. 

An exception is “hoists ready for operation” acc. validated national regulations with EU-declaration of 
conformity. 

Definition “qualified person” (former expert) 

A “qualified person” has learned, due to occupational training and experience and the job that the person has 
done, the skills needed to tests the material for one’s work. 

Definition “licensed qualified person” (former approved expert) 

A “licensed qualified person” has, due through special occupational training, knowledge about testing of the 
material for one’s work and knows the national accident prevention  regulations and other prescriptions and 
technical regulations. This person must test the material for one’s work regularly with regard to design and 
kind of use. The license will be given to qualified person be the approved supervision authorities (ZÜS). 

 

8.2 

Load chain 

  Before commissioning the load chain must be aligned and oiled. 

  For the first commissioning of motorized hoists, chain oil is supplied with the delivery. 

  Move safety note and fixing wire away from the chain. 

 

   

CAUTION!

 

Do not use grease for lubrication of load chain. 

Without lubrication, manufacturer's warranty and/or liability will be void. 

 

 

NOTICE!

 

Continuous, thorough lubrication will increase the life of the chain considerably. 

 

Safety check 

 

 

Before putting into service initially or when putting back into service, it must be checked whether: 

  All fastening screws (if existent), socket pins, flap socket and safety devices are tightened and secured. 

 

  The chains are correctly placed, oiled and in good condition. 

 

 

10 

Maintenance 

 

 

10.1 

General 

All monitoring, servicing and maintenance operations are to ensure correct functioning of the equipment; 
they must be effected with utmost care. 

  Only “qualified persons” may do this work. 

  Servicing and maintenance work must only be done when the hoist is not loaded. 

  Records must be kept of all test results and measures taken. 

 

Summary of Contents for 53/09-EX

Page 1: ...B c T3 or II 2D c 200 C DANGER Not to be used with IIC gases and IIB gases hydrogen sulphide and ethylene oxide and light metal and shock sensitive dusts It is not allowed to use the equipment in area...

Page 2: ...Table of Contents 1 Information 3 2 Safety 4 2 1 Warning notice and symbols 4 2 2 Duty of care of the owner 4 2 3 Requirements for the operating personnel 5 2 4 Appropriate use 5 2 5 Basic safety meas...

Page 3: ...ion of hoists the national accident prevention apply in Germany amongst others Lifting equipment for use in areas prone to explosion complies with current legislation standards and regulations and is...

Page 4: ...s load attaching devices as well as main energy supply lines must be assembled according to the valid rules and regulations For explosion proof equipment all these parts must be approved for use in ar...

Page 5: ...ion carried out by a licensed qualified person The permissible ambient temperature during operation of manual driven devices is 20 C 50 C and at all power driven devices 20 C 40 C Defective devices an...

Page 6: ...ediate vicinity must be informed by calling to them Please pay attention to the regulations for load carrying devices UVV for both positive and non positive methods of attaching loads The lifting tack...

Page 7: ...s Never remove dust with compressed air remove it with a wet bolt of cloth Defective units or units that show abrasion of its surface rust on chains hooks or suspension devices must be taken out of se...

Page 8: ...ice category 2 2 Expl group of gases IIB IIB Temperature class gases Temperature class dust T4 135 C T3 200 C DANGER The classification for the device can be found on the EX type plate on the unit The...

Page 9: ...o zones The owner must determine the zone that exists Information on the zone classification can be found in IEC 60079 10 and in national standards The following table contains an overview of the zone...

Page 10: ...10 5 52 185 01 01 02 2 6 4 Explosion hazards recognizing and preventing...

Page 11: ...vice 4 Description 4 1 Areas of application The devices must be as far as possible installed in a covered room If they are used in the open protect the units against the effects of weather such as rai...

Page 12: ...de from steel plate or aluminium Load chain According to EN 818 7 T high quality chain All components match precisely to each other Therefore please only use original chains Load hook with safety catc...

Page 13: ...be changed either by the load nor by other influences 6 1 Tools 7 Operation Only people that are familiar with the operation of the lifting devices and cranes may be entrusted with their operation The...

Page 14: ...wheeling OFF Illustration 10 7 2 Brake and pawl The brake system needs a minimum load of 3 of the capacity Only this minimum load makes sure that the load pressure brake closes correctly When the bra...

Page 15: ...k and knows the national accident prevention regulations and other prescriptions and technical regulations This person must test the material for one s work regularly with regard to design and kind of...

Page 16: ...hich is open at the side A chain link which is open at the side can easily be produced by grinding out a small piece The opening must have the same thickness as the chain link Illustration 11 Hang a n...

Page 17: ...ne or several of the dimensions fall below or exceed the dimensions in the table or if cracks or corrosion are found the parts must be replaced with original spare parts 11 2 Checking the load chain C...

Page 18: ...sured values before commissioning Capacity t X or Y mm H mm CAUTION When the dimension of hook opening width is deformed more than 10 or when the dimension of the hook bottom thickness is fallen short...

Page 19: ...the switching area from a lifting to a lowering movement must be given special attention Thoroughly effected lubrication of the chain will prolong the life of the chain by approx 20 times compared to...

Page 20: ...nominal load and normal operation conditions Use by heavy conditions can shorten the product lifetime In these cases the thickness of the brake lining must be checked more than 1x yearly The ratchet w...

Page 21: ...s Defect of chain gear or chain wheels Do maintenance and replace defective parts by original spare parts Load is lifted with interruptions Pawl spring is missing or defective Do maintenance and repla...

Page 22: ...e as above Also read the chapter Transport and storage 15 2 Final decommissioning disposal Measures are as above After disassembly ensure that the disposal of the equipment and any materials it contai...