background image

 

 

 

 

5.52.693.00.01.00 

 

 

15 

 

16 

Remedy 

 

 

Problem* 

Unit 

Cause 

Remedy 

Unit cannot be switched on 

Electric trolley 

No main power 

Check connection to mains supply

 

Phase sequence not correct (with low voltage control) 

Exchange 2 phases 

(see wiring note at the plug) 

Motor runs in opposite direction  

Electric trolley 

Phase sequence / rotating field wrong 
(with three-phase direct control) 

Exchange 2 phases 

(see wiring note at the plug)

 

Motor does not run

 

Electric trolley 

Fuse burnt out

 

Replace the fuse

 

Defective switching unit in the control button switch

 

Replace the switching unit

 

Interruption in the control cable

 

Check control cable and replace if necessary.

 

Defect of capacitor (only for one-phase alternating 

current) 

Replace the capacitor 

Overheat protection has tripped* 

Allow engine to cool 

Defective coil - mechanic or electric overload

 

Motor must be repaired by a specialist 

If the unit is suitable for explosive atmospheres, the 
motor must be returned to the manufacturer for repair!*

 

Pneumatic 

trolley 

Operation pressure / quantity of air is too low 

Check connection to mains supply 

After prolonged standstill 

See maintenance - pneumatic motor 

Motor runs – trolley does not move

 

Motor driven 

trolley 

No or incorrect power transmission 

Check driving pinion and repair if necessary, 

check condition of trolley wheels / contact to main 

beam surface and repair / adjust if necessary 

If the unit is suitable for explosive atmospheres, please 
clarify with the manufacturer what to do!*

 

Motor hums and uses excessive current 

 

Electric trolley 

Defective coil

 

Motor must be repaired by a specialist 

If the unit is suitable for explosive atmospheres, the 
motor must be returned to the manufacturer for repair!*

 

Rotor is rubbing

 

(Optional) brake does not release

 

See problem “(Optional) brake does not release”

 

Defect of capacitor 

(only for one-phase alternating current) 

Replace the capacitor 

Defect of starter relay 

(only for one-phase alternating current) 

Replace the starter relay 

Phase failure (only three-phase direct control) 

Find the cause and repair 

Motor does not brake or has excessive afterrunning.

 

Electric trolley 

Switching error after intervention in the electric circuit

 

Check the electric connection of the brake acc. to 

the wiring diagram 

Motor driven 

trolley 

Brake linings are worn or dirty.

 

Brake lining carrier must be changed completely 

If the unit is suitable for explosive atmospheres, the 
motor must be returned to the manufacturer for repair!*

 

Air gap is too large

 

Re-adjust the air gap 

If the unit is suitable for explosive atmospheres, the 

motor must be returned to the manufacturer for repair!*

 

(Optional) brake does not release

 

Electric trolley 

Brake rectifier defective

 

Replace the brake rectifier 

If the unit is suitable for explosive atmospheres, the 
motor must be returned to the manufacturer for repair!*

 

Brake current relay defective

 

Replace the brake current relay 

If the unit is suitable for explosive atmospheres, the 
motor must be returned to the manufacturer for repair!*

 

Brake coil is defective 

Replace the brake coil 

If the unit is suitable for explosive atmospheres, the 

motor must be returned to the manufacturer for repair!*

 

Permissibe air gap is exceeded due to worn out brake 

lining

 

Re-adjust the air gap and exchange the brake lining 

if necessary 

If the unit is suitable for explosive atmospheres, the 
motor must be returned to the manufacturer for repair!*

 

Power drop in the mains power line > 10%

 

Provide correct power supply voltage

 

Pneumatic 

trolley 

Operation pressure / quantity of air is too low 

Check connection to mains supply 

Fuses burnt out or motor contactor is triggered

 

Electric trolley 

Short circuit in component

 

Eliminate the short circuit

 

Motor has a short circuit in the body or windings

 

Correct the problem by a specialist 

If the unit is suitable for explosive atmospheres, the 
motor must be returned to the manufacturer for repair!*

 

Motor is switched incorrectly

 

Correct the switching

 

Wrong type of fuse

 

Replace the fuse with correct one

 

Trolley runs very slowly or not at all 

All trolleys 

Driving pinion dirty or blocked. 

Clean the driving pinion and lubricate it, if necessary, 

exchange worn parts 

Hand geared 

trolley 

Hand chain is twisted or blocked 

Place the hand chain correctly 

*) as far as applicable 

 

17 

Decommissioning 

 

 

   

WARNING!

 

It is essential that the following points are observed in order to prevent damage to the equipment or critical 
injury when the device is being decommissioned: 

 

 

 

It is mandatory that all steps for decommissioning the machine are carried out in the indicated sequence: 

  First secure the working area for decommissioning, leaving plenty of space. 

  Read the chapter "Safety instructions". 

  Disassembly is carried out in reverse order to the assembly.  

  Please make sure that all operating material is disposed of in accordance with environmental regulations. 

Summary of Contents for 32/20

Page 1: ...onorail Trolley Type 32 20 as monorail push travel trolley R as monorail hand geared trolley H as monorail electric trolley E as monorail pneumatic trolley P as swivelling Trolleys Installation Operat...

Page 2: ...Contents 1 Information 3 2 Safety 3 2 1 Warning notice and symbols 3 2 2 Duty of care of the owner 4 2 3 Requirements for the operating personnel 4 2 4 Appropriate use 5 2 5 Basic safety measures 5 3...

Page 3: ...claims require adherence to all instructions in this manual Before delivery all products are packed properly Check the goods after receipt for any damage caused during transport Report any damage imm...

Page 4: ...he device is only operated in a fault free fully functional condition and the safety components in particular are checked regularly to ensure that it is functioning properly The required personal prot...

Page 5: ...ndication label in reactor containment vessels to transport people The device is not suitable for use on stages and in studios Persons must not stand under a suspended load NOTICE If the units are not...

Page 6: ...o not throw or drop the equipment Use adequate means of transport Transport and means of transport must be suitable for the local conditions 3 2 Safety device for transport NOTICE Should a safety devi...

Page 7: ...treme environmental impact is the regular use of the equipment 4 4 Important components Wheels Machined wheels with maintenance free roller bearings Profiled wheel surfaces for the use on all standard...

Page 8: ...type leave a distance for the load hook It is important that the load hangs in the middle under the beam so that the two side plates are equally loaded The suspension eye 9 if existent for bigger load...

Page 9: ...to adjust the beam flange width dismantle the safety screws 3 at one trolley side After adjustment of dimension X and installation on the beam install the safety screws 3 again and secure them with a...

Page 10: ...nd chain Control buttons Control symbols shown are for optical information only and can vary depending on the control module Emergency stop Illustration 3 Arrow keys drive left right Illustration 4 Sy...

Page 11: ...000 kg capacity and without motor driven trolleys of hoisting unit must be tested by a qualified person before putting into operation for the first time Hoists of 1000 kg capacity and up or with more...

Page 12: ...and check the positions of the end stops 12 Maintenance 12 1 General All monitoring servicing and maintenance operations are to ensure correct functioning of the equipment they must be effected with u...

Page 13: ...crews 8 from the magnetic body clockwise 5 Tighten the locking screws 6 6 Check the air gap again and re adjust if necessary Illustration 10 13 Inspection 13 1 Periodic checks Independently from the r...

Page 14: ...the oiler of the maintenance unit Recommendation Should longer periods of standstill be foreseen insert some cm of oil into the air supply hose after the last use of the unit and let the motor run sho...

Page 15: ...be changed completely If the unit is suitable for explosive atmospheres the motor must be returned to the manufacturer for repair Air gap is too large Re adjust the air gap If the unit is suitable fo...

Page 16: ...rried out in accordance with environmental regulations 18 Additional documents 18 1 Electric wiring diagrams Electric wiring diagrams are attached to the consignment or included in the terminal box Ex...

Reviews: