5.52.131.00.01.09
7
The devices are not suitable for continuous operation. The duty cycles of the motors (see the technical
data chapter) as well as the remaining life time of the equipment in accordance with FEM group and
usage (see calculation of remaining safe working period) must be observed.
WARNING!
The following is not allowed:
to lift another load than the nominal safe working load
to manipulate the sliding clutch if units are equipped with
The use of elongated or damaged chains or wire ropes. Replace them immediately by new, original
parts.
Never loop the load chain around a load nor place or pull the chain over edges.
Never repair damaged load hooks (e.g. by hammering), but replace them by original hooks.
3
Transport and Storage
CAUTION!
Transport may only be done by qualified personnel. No liability for any damage resulting from improper
transport or improper storage.
3.1 Transport
The devices are checked and if so adequately packed before delivery.
Do not throw or drop the equipment.
Use adequate means of transport.
Transport and means of transport must be suitable for the local conditions.
3.2
Safety device for transport
NOTICE!
Should a safety device for transport exist, please remove it before commissioning.
3.3 Storage
Store the equipment at a clean and dry place.
Protect the equipment against dirt, humidity and damage by an appropriate cover.
Protect hooks, wire ropes, chains and brakes against corrosion.
4 Description
4.1
Areas of application
The devices must be as far as possible installed in a covered room.
If they are used in the open, protect the units against the effects of weather such as rain, hail, snow, direct
sunshine, dust, etc. - we recommend to use a cover in parking position. If the device is set up in a
continuously humid environment with strong temperature fluctuations, the correct functionings are
endangered by the forming of condensation.
Ambient temperature -20°C up to +50°C. Power-operated units -20 up to +40°C. Humidity 100 % or less but
not under water
During longer periods of standstill, corrosion may reduce the function of the brake.
DANGER!
It is not permitted to use the unit in an area at risk from explosion!