background image

17

Manual 

JetiBox

11.  MASTER-Spin-Controller - Technical Datas

Typ

Betriebsspannung/Zellenzahl

Maße 
(mm)

Innenwi-

derstand 
(mOhm)

Swit-
ching 

BEC

Max. 

Servo-
anzahl

Helimodus 
aktivierbar

Gewicht in 

Gramm

Strom 
Dauer 

(2,2Ah 

batt.)

FETs

MasterSpin 11

5-12NC /2-4 LiPo/5-17V

32x23x6

2 x 8

6

12

11

6

MasterSpin 22

5-12NC /2-4 LiPo/5-17V

32x23x7

2 x 4

6

18

22

12

MasterSpin 33

5-14NC /2-5 LiPo/5-21V

42x23x7

2 x 2,6

7

30

33

18

MasterSpin 44

6-18NC /2-6 LiPo/6-26V

52x25x10

2 x 2,0

8

40

44

24

MasterSpin 55

6-24NC /2-8 LiPo/6-34V

52x25x15

2 x 1,1

8

56

55

48

MasterSpin 66

6-18NC /2-6 LiPo/6-26V

52x25x12

2 x 1,0

8

50

70

48

MasterSpin 70 Opto

6-18NC /2-6 LiPo/6-26V

52x25x12

2 x 1,0

50

70

48

MasterSPIN 48 

Opto

14-30NC /4-10 LiPo/12-42V

52x25x12

2 x 2,5

45

48*

48

MasterSpin 75 0pto

14-30NC /4-10 LiPo/12-42V

52x25x15

2 x 1,6

55

75*

72

MasterSpin F5B 

Opto

8-18NC /3-6 LiPo/7-26V

52x25x16

2 x 0,25

n.a.

55

200**

96

MasterSpin F5D 

Opto

6-16NC /2-5 LiPo/5-24V

52x25x12

2 x 0,33

n.a.

50

140**

72

MasterSpin F5F 

Opto

6-16NC /2-5 LiPo/5-24V

52x25x14

2 x 0,66

n.a.

50

125**

72

MasterSpin 77 0pto

14-36NC /4-12 LiPo/12-50V

75x55x17

2 x 1,25

105

75

48

MasterSpin 99 0pto

14-36NC /4-12 LiPo/12-50V

75x55x17

2 x 1,1

105

90

48

MasterSpin 200 

Opto

24-40NC /6-14 LiPo/18-59V

63x120x27

2 x 0,8

n.a.

270

200

30

MasterSpin 300 

Opto

24-40NC /6-14 LiPo/18-59V

63x120x27

2 x 0,5

n.a.

460

300

30

MasterSpin 70 

NAVY

6-14NC /2-5 LiPo/6-21V

52x25x15

2 x 1,0

8

n.a.

65

70

48

MasterSpin 99 

NAVY

14-30NC /4-10 LiPo/12-42V

75x55x22

2 x 1,1

n.a.

115

90

48

Type

Operating Voltage / Cell count

Dimensi-

ons (mm)

Resistance 

(mOhm)

Swit-
ching 

BEC

Max. 

Servo-

number

Helimode

/ constant 

RPM 

inside

Weight in 

Grams

Nomina-

Current  
(2,2Ah. 

batt)

FETs

* mit guten Kühlung und Umgebungstemperatur unter 20°C

* with good cooling and outside temperature under 20°C

** gilt für Wettbewerbstypische Einschaltzeiten

** valid for typical runtime in competition

Summary of Contents for JETIBOX

Page 1: ...Manual JETIBOX for advanced programming of MasterSpin Speedcontroller ...

Page 2: ...lities our new Controller Line offers Although the programming sequences of MasterSpin Speedcontrollers are particularly logical and therefore easy to perform using and operating requires some knowledge and a few basic skills Please read the entire manual thoroughly before attempting to operate this electronic device Especially important are our safety instructions which must be observed in any ca...

Page 3: ...rt when the engine is running at least 20 feet away Mechanical or electrical damages can cause the motor to run unexpected and unintentionally Make sure the motor is always properly mounted even for test runs Check regularly that all screws of your drive are securely fas tened Protect the JetiBox against any vibrations dust wet hits or pressures Check the JetiBox regularly for damages Should the e...

Page 4: ...quential damages resulting from our delivery or our workmanship As far as is legal ly admitted with which legal arguments ever the obligation to the compensation is limited to the invoice amount of the affected product This does not apply as far as we must avouch unrestrictedly after compelling laws or for rough negligence 3 Product description The JetiBox is sophisticated electronic device and es...

Page 5: ...additional R X pack while using for setup you MasterSpin ESC MasterSpin ESC is not included in delivery with your JetiBox Please check how to use the manual which is added in the MasterSpin ESC supply LC Display Power Supply Not necessary for MasterSpin setup Keys D down U up L left R right Controller Connection MasterSpin Battery Motor Programming of MasterSpin ESCs ...

Page 6: ...signated with Connect the flight batteries and switch on the switch void for Spin11 On the display ap pears the name of the connected controller By means of the push buttons L and P more detailed informations are acquired of your controller By means of the push button D we get to the option line of basic régimes where we either can choose reading out of measured values or setting of controller par...

Page 7: ...OLLER TYPE Imax 44A CONTROLLER TYPE BEC 5 5V 3A 5A For excample MasterSpin 44 CONTROLLER TYPE MasterSpin 44 Operating Voltage Maximum Current OPTO or BEC MeasureOrSetting MEASURE MeasureOrSetting MAN SETTING MeasureOrSetting Auto set goto MEASURE goto MAN SETTING goto Auto set ...

Page 8: ...Manual JetiBox 8 ...

Page 9: ...Manual JetiBox 9 ...

Page 10: ...Manual JetiBox 10 ...

Page 11: ...Manual JetiBox 11 ...

Page 12: ...Manual JetiBox 12 ...

Page 13: ...Manual JetiBox 13 ...

Page 14: ...Manual JetiBox 14 7 1 Programming options with JetiBox R R R R R L L Measure Manual Setting Auto Setting R ...

Page 15: ...ions like for example short circuits or a reversed polarity of power battery The Speed Controller protections switch the motor off if The Speed Controller reaches a temperature of 100 C 215 F This is the basic setup and can be adjusted with the JetiBox However this does not protect against short cuts The battery voltage drops under the minimal operating voltage of the respective type The current d...

Page 16: ...etness avoid warranty claims This is also considered for faults based on strong wear or excessive vibrations Further claims for example secondary damages are expelled The liability for losses by the device or its application is also expelled Any shipping to Hacker Motor GmbH must be free of charge unfree shipping will not be accepted We can not take any responsibility for transport damages or loss...

Page 17: ... Opto 8 18NC 3 6 LiPo 7 26V 52x25x16 2 x 0 25 n a 55 200 96 MasterSpin F5D Opto 6 16NC 2 5 LiPo 5 24V 52x25x12 2 x 0 33 n a 50 140 72 MasterSpin F5F Opto 6 16NC 2 5 LiPo 5 24V 52x25x14 2 x 0 66 n a 50 125 72 MasterSpin 77 0pto 14 36NC 4 12 LiPo 12 50V 75x55x17 2 x 1 25 105 75 48 MasterSpin 99 0pto 14 36NC 4 12 LiPo 12 50V 75x55x17 2 x 1 1 105 90 48 MasterSpin 200 Opto 24 40NC 6 14 LiPo 18 59V 63x1...

Page 18: ...cial cases My motor has no brake any more Is my motor dama ged No In most cases it s not the motor s fault Most probably the Speed Control ler is set to other mode by accident This can happen if the controller is started up while the throttle stick is in full power position Please check if can hear only one Beep after start up of the Speed Controller In case you hear two Beeps change the mode to y...

Page 19: ...he throttle stick ATV adjustment is not set to 100 for both side or the throttle stick is not in the proper motor stop position when the Speed Controller is started up In mode automatic initial point the Speed Con troller may assume a higher throttle stick position as motor stop position This reduces the usable throttle stick resolution As result the Speed control ler can t be commanded fully sens...

Page 20: ... Europäischen Union Dieses Symbol ist nur in der Europäischen Union gültig Information on Disposal for Users of Waste Electrical and Electronic Equipment private households This symbol on the products and or accompanying documents means that used electrical and electronic products should not be mixed with general household waste For proper treatment recovery and recycling please take these product...

Reviews: