Installation
W A R N I N G
Multiple hazards. Only qualified personnel must conduct the tasks described in this section of the
document.
Mechanical installation
D A N G E R
Risk of injury or death. Make sure that the wall mounting is able to hold 4 times the weight of the
equipment.
W A R N I N G
Personal injury hazard.
Instruments or components are heavy. Use assistance to install or move.
The object is heavy. Make sure that the instrument is securely attached to a wall, table or floor for a
safe operation.
This instrument is rated for an altitude of 2000 m (6562 ft) maximum. Use of this instrument at an
altitude higher than 2000 m can slightly increase the potential for the electrical insulation to break
down, which can result in an electric shock hazard. The manufacturer recommends that users with
concerns contact technical support.
Install the analyzer indoors, in a non-hazardous environment. Refer to the supplied mounting
documentation.
Plumbing
D A N G E R
Fire hazard. This product is not designed for use with flammable liquids.
N O T I C E
Do not install reagents until all plumbing is complete.
Make sure to use the specified tubing size.
Sample line guidelines
Select a good, representative sampling point for the best instrument performance. The sample must
be representative of the entire system.
To prevent erratic readings:
• Collect samples from locations that are sufficiently distant from points of chemical additions to the
process stream.
• Make sure that the samples are sufficiently mixed.
• Make sure that all chemical reactions are complete.
Connect the sample stream
Install each sample line into the center of a larger process pipe to minimize interference from air
bubbles or bottom sediment.
shows examples of good and bad installation.
Keep the sample lines as short as possible to prevent the accumulation of bottom sediment. The
sediment can absorb some of the analyte from the sample and cause low readings. The sediment
can later release the analyte and cause high readings. This exchange with the sediment also causes
a delayed response when the analyte concentration in the sample increases or decreases.
8
English
Summary of Contents for 5500sc
Page 2: ...English 3 Fran ais 18 Espa ol 35 52 2...
Page 54: ...54...
Page 56: ...1 2 3 4 5 pH 1 2 56...
Page 57: ...1 1 5 9 2 6 SD 10 3 7 1 11 4 8 12 2 1 57...
Page 58: ...4 2000 6562 2000 3 58...
Page 59: ...3 1 2 4 4 1 2 5 9 2 6 10 1 3 2 7 4 1 8 59...
Page 60: ...6 5 6 6 1 4 1 5 1 3 5 2 4 60...
Page 61: ...6 1 3 5 2 4 6 30 42 2 60 30 42 2 60 GFCI GFI PE 61...
Page 62: ...7 7 1 3 8x 2 3x 4 8x 8 8 62...
Page 63: ...9 52 9 1 4 7 2 5 8 3 4 20 6 9 0 1 63...
Page 64: ...1 0 2 18 AWG 3 10 52 3 4 10 3 1 PE 2 N 3 L1 4 1 PE 2 24 3 24 64...
Page 65: ...10 SC 6773200 sc sc Smart Probe Adapter 9321000 Smart Probe Adapter 11 65...
Page 66: ...11 1 0 2 18 AWG 2x 63 NO COM NC 4 20 4 20 4 20 2 Modbus 49937 66...
Page 67: ...40007 40008 12 0 0 8 2 5 30 63 12 TTL 1 12 3 TTL 2 2 4 2 DIG6 67...
Page 68: ...MSDS SDS 133 13 3 68...
Page 69: ......