1.6
Limit switch
Hook observation
The limit switch stops the hoisting movement when the hook is pulled against the housing or when the rope shaft is swivelled
forwards (insert rope).
-
The limit switch only responds when the motor is rotating in the correct direction (the rotary field of the
power connection).
1.7
Lowering and breaking
You can place the load precisely in the desired position using the control buttons UP/DOWN.
Breaking during lowering takes place using the motor without an energetic recovery system in the mains. When stationary or
powered off, this takes place using the spring-loaded holding brake. As this energy is converted into heat, the output due to
heat in the control box is limited during lowering.
-
Heavier loads may only be lowered over short distances.